Technical data
9.1 Readings on display
Important
The readings are valid when operating under reference conditions. See the
section
The main screen is shown, indicating the actual outlet pressure and status of
the compressor. To call up other information such as actually measured
pressures and temperatures, see the sections Inputs menu and Outputs menu.
Important readings
Compressor outlet pressure
bar(e) (psig)
Depends on programmed
unloading and loading
pressures
Pressure drop over air filters
bar
Below 0.05
Pressure difference over oil separator
bar
Below 0.8
Oil injection pressure at the compressor elements
bar(e) (psig)
Depends on programmed
unloading and loading
pressures
Compressor outlet temperature, air-cooled compressors
˚C
Approx. 29
Compressor stage outlet temperature
˚C
Between 70 and 100
Cooling air temperature
˚C
Below 46
9.2 Reference conditions
Reference conditions
Absolute inlet pressure
bar(a)
1
Relative air humidity
%
0
Air inlet temperature
˚C
20
Nominal working pressure
Refer to the
Compressor
data
section