Instruction book
66
909935AIB
5.6 Manual loading/unloading
Description
Control panel
Reference
Designation
Function
1
Touchscreen
Shows the compressor operating condition and a
number of icons to navigate through the menu.
The screen can be operated by touch.
2
Warning sign
Flashes in case of a shut-down, is lit in case of a
warning condition.
3
Service sign
Is lit when service is needed.
4
Operation sign
Is lit when the compressor is running in automatic
operation.
5
Voltage sign
Indicates that the voltage is switched on.
6
Stop button
This button stops the compressor.
7
Start button
This button starts the compressor. The operation
sign (4) lights up. The controller is operative.
General
Normally, the compressor runs in automatic operation, i.e. the electronic regulator loads, unloads,
stops and restarts the compressor automatically. Operation sign (4) is then alight.
If required, the compressor can be unloaded manually. In this case, the compressor is switched
out of automatic operation i.e. the compressor remains running unloaded unless it is loaded
again manually.
Manual unloading