Instruction book
68
909935AIB
Reference
Designation
Function
4
Operation sign
Is lit when the compressor is running in automatic
operation.
5
Voltage sign
Indicates that the voltage is switched on.
6
Stop button
This button stops the compressor.
7
Start button
This button starts the compressor. The operation
sign (4) lights up. The controller is operative.
Procedure
Frequently stopping the compressor using the emergency stop button may damage the
compressor. Only use the emergency stop button in case of emergency.
Step
Action
1
Press stop button (6). The compressor will coast down and then stop.
2
To stop the compressor in case of emergency, press the emergency stop button. The
warning sign (2) starts flashing. After remedying the trouble, unlock the emergency stop
button by pulling it back.
3
Close the air outlet valve.
4
Open the condensate drain valves.
5
Switch off the voltage.
5.8 Taking out of operation
Disconnecting the compressor
At the end of the service life of the compressor, proceed as follows:
Step
Action
1
Stop the compressor and close the air outlet valve.
2
Switch off the voltage and disconnect the compressor from the mains.
3
Depressurize the compressor by opening the drain valve and loosening the oil filler plug
one turn.
4
Shut off and depressurize the part of the air net which is connected to the outlet valve.
Disconnect the compressor air outlet pipe from the air net.
5
Drain the oil and condensate circuits.
6
Disconnect the compressor condensate piping from the condensate drain net.