82
P/N 115109 - Direct Vent Option Installation Instructions
Electrical Connections for the Optional Direct Vent Fan
(Supplied By Champion)
Champion Vent Fan Terminal Block
120VAC/50-60/1
Terminal
Block
L
Champion Vent Fan Terminal Block
Wiring Diagram
M
! IMPORTANT !
Electrical installation must be performed by
qualified personnel in accordance with
all local codes and regulations or in the
absence of local codes then the National
Electrical Code.
DO NOT CONNECT POWER
UNTIL THE FAN IS COMPLETELY
INSTALLED.
1. The Champion supplied vent fan is
120VAC/50-60/1.
2. Incoming power is connected to the
vent fan terminal block located in the
vent fan junction box on the side of the
vent fan assembly.
(See Figure L).
3. Grounding of the vent fan is not
required because the fan motor is
isolated within the vent fan plastic
housing.
4. Connect the 120VAC power supply
to the vent fan terminal block.
(See Figure M).
5. If the 12 ft. [3.7 m] vent fan cable
supplied with the direct vent fan
control box is not long enough for the
installation, the installer may replace
the cable with a longer cord of the
same electrical specifications.
6. Refer to Figure N on the next
page for the direct vent fan control box
cable wiring diagram.
WARNING
:
Electrocution or serious injury may result when
working on an energized circuit.
Disconnect power at the main breaker or service
disconnect switch before working on the circuit.
Lock-out and tag the breaker to indicate that work is
being performed on the circuit.
Summary of Contents for DH5000T Series
Page 17: ...9 Blank Page This Page Intentionally Left Blank ...
Page 40: ...32 Wash Pump Motor Assembly 12 11 10 14 13 9 8 7 6 5 4 1 2 3 ...
Page 48: ...40 Booster Assembly All Models and Options 1 2 2 3 4 3 5 8 15 9 10 11 13 12 12 13 14 7 6 ...
Page 50: ...42 Control Panel Assembly 2 3 6 7 8 5 1 4 9 10 ...
Page 58: ...50 Wash and Rinse Spray Arm Assemblies 1 2 5 6 3 4 1 8 2 7 6 7 5 4 3 ...
Page 62: ...54 Track and Panel Assemblies 9 4 3 6 1 1 5 10 8 7 2 11 12 13 13 14 15 ...
Page 74: ...66 Drain Water Tempering Assembly 1 2 3 4 3 5 5 6 7 8 9 10 11 12 14 13 15 ...
Page 76: ...68 Dish Racks Line Strainer PRV 1 2 3 4 ...
Page 108: ...100 Blank Page This Page Intentionally Left Blank ...
Page 110: ...102 Blank Page This Page Intentionally Left Blank ...
Page 113: ...105 Standard Model DH5000T Electrical Schematic ...
Page 114: ...106 Direct Vent Option Model and Condensate Removal Option Model DH5000T Electrical Schematic ...