8
1.
Connect the incoming power flexible conduit to the incoming conduit mounting bracket
located on the rear of the dishwasher base making sure to leave 6 feet [2 m] of excess
conduit and conductors to allow for servicing of the dishwasher.
2.
Route the power conductors through the 1-1/2" rigid PVC Power Cable Conduit to the
front of the dishwasher as shown.
(See A and B below).
3.
Two cable tie mounts are provided on the base of the machine to secure the conductors.
Make sure the conductors do not block the front of the booster tank,
(if equipped)
, so the
booster can be serviced easily.
4.
Refer to the terminal block connection diagrams below and connect the incoming
power to the input terminal block as indicated according to the machine's power
requirements.
(See C and D below).
5.
CHECK MOTOR ROTATION FOR 208-240/460-480V/60/3 ONLY
. Check the rotation
direction of the wash pump motor according to the indicator arrow on the motor end
cover and reverse L1 and L2 at the input terminal block if the motor rotation is incorrect.
Installation
Electrical Connections
Connecting Incoming Power Supply
(continued)
SINGLE PHASE
POWER CONNECTION
208-240V/60/1
LINE IN
GND
NOT
USED
L1
L2
L3
L1
L2
THREE PHASE
POWER CONNECTION
208-240/440-480V/60/3
GND
LINE IN
L1
L2
L3
L1
L2
L3
D
C
Power Cable Bracket
Power Cable Conduit
A
B
Summary of Contents for DH5000T Series
Page 17: ...9 Blank Page This Page Intentionally Left Blank ...
Page 40: ...32 Wash Pump Motor Assembly 12 11 10 14 13 9 8 7 6 5 4 1 2 3 ...
Page 48: ...40 Booster Assembly All Models and Options 1 2 2 3 4 3 5 8 15 9 10 11 13 12 12 13 14 7 6 ...
Page 50: ...42 Control Panel Assembly 2 3 6 7 8 5 1 4 9 10 ...
Page 58: ...50 Wash and Rinse Spray Arm Assemblies 1 2 5 6 3 4 1 8 2 7 6 7 5 4 3 ...
Page 62: ...54 Track and Panel Assemblies 9 4 3 6 1 1 5 10 8 7 2 11 12 13 13 14 15 ...
Page 74: ...66 Drain Water Tempering Assembly 1 2 3 4 3 5 5 6 7 8 9 10 11 12 14 13 15 ...
Page 76: ...68 Dish Racks Line Strainer PRV 1 2 3 4 ...
Page 108: ...100 Blank Page This Page Intentionally Left Blank ...
Page 110: ...102 Blank Page This Page Intentionally Left Blank ...
Page 113: ...105 Standard Model DH5000T Electrical Schematic ...
Page 114: ...106 Direct Vent Option Model and Condensate Removal Option Model DH5000T Electrical Schematic ...