89
P/N 115107 - Condensate Removal Option Installation Instructions
Model DH5000T Condensate Removal Option Description
91 34
[2331]
"
70 18
[1781]
Machine
Height
Direct Vent
Mounted
"
22
[559]
"
~
~
Condensate
Removal
Shroud
A
C
1-7/8"
[48]
5-1/8"
[130]
Min.
Machine
Mounted
Direct
Vent Fan
Control Box
B
The condensate removal option is a stainless steel vent shroud (approx. weight 60 lbs./27 kg)
and a control box mounted on the left side of the dishwasher.
1. The condensate removal shroud
is mounted on the top rear of the
dishwasher using (4) 1/4-20 x 1/2" SST
truss head screws.
(See Figure A).
2. The shroud must be installed before the
dishwasher is permanently placed and
before connecting the utilities.
3. The DH5000T minimum distance to
the back wall is 1-7/8" [48mm] for
straight-through operation. If the
dishwasher is configured for corner
operation, then the minimum distance
to the back wall is 1-7/8" [48mm] and
5-1/8" [130mm] from the right wall.
(See Figure B).
4. Only a 3/4" NPT cold water supply
is required for the Condensate
Removal Option
(See Figure B).
! ATTENTION !
The condensate removal shroud must be installed before the dishwasher is permanently
placed and before the utilities are connected.
! VERY IMPORTANT !
The incoming cold water supply
pressure must be a minimum
of 45 PSI flowing pressure measured
at the dishwasher inlet connection.
Summary of Contents for DH5000T Series
Page 17: ...9 Blank Page This Page Intentionally Left Blank ...
Page 40: ...32 Wash Pump Motor Assembly 12 11 10 14 13 9 8 7 6 5 4 1 2 3 ...
Page 48: ...40 Booster Assembly All Models and Options 1 2 2 3 4 3 5 8 15 9 10 11 13 12 12 13 14 7 6 ...
Page 50: ...42 Control Panel Assembly 2 3 6 7 8 5 1 4 9 10 ...
Page 58: ...50 Wash and Rinse Spray Arm Assemblies 1 2 5 6 3 4 1 8 2 7 6 7 5 4 3 ...
Page 62: ...54 Track and Panel Assemblies 9 4 3 6 1 1 5 10 8 7 2 11 12 13 13 14 15 ...
Page 74: ...66 Drain Water Tempering Assembly 1 2 3 4 3 5 5 6 7 8 9 10 11 12 14 13 15 ...
Page 76: ...68 Dish Racks Line Strainer PRV 1 2 3 4 ...
Page 108: ...100 Blank Page This Page Intentionally Left Blank ...
Page 110: ...102 Blank Page This Page Intentionally Left Blank ...
Page 113: ...105 Standard Model DH5000T Electrical Schematic ...
Page 114: ...106 Direct Vent Option Model and Condensate Removal Option Model DH5000T Electrical Schematic ...