background image

4

110524

Limited Warranty

This warranty is extended to the original purchaser of an evaporative cooler installed and used under normal conditions.  It does not cover
damages incurred through accident, neglect, or abuse by the owner.  We do not authorize any person or representative to assume for us any
other or different liability in connection with this product.

Terms And Conditions Of Warranty

From the date of purchase, if any original component part provided by Champion Cooler fails due to defect in material or factory
workmanship only, we will provide the replacement part as follows:

Eight Years on the original base assembly if water leakage should occur due to rust out.
Two years on the rigid evaporative media (RLD2 models only).
One Year on all other original component parts.

Exclusions From The Warranty

We are not responsible for replacement of cooler pads on RLD units.  These are disposable components and should be replaced periodically.
We are not responsible for any incidental or consequential damage resulting from any malfunction.

We are not responsible for any damage received from the use of water softeners, chemicals, descale material, plastic wrap, or if a motor of
a higher horsepower than what is shown on the serial plate is used in the unit.

We are not responsible for the cost of service calls to diagnose cause of trouble, or labor charge to repair and/or replace parts.

How To Obtain Service Under This Warranty

Contact the Dealer where you purchased the evaporative cooler.  If for any reason you are not satisfied with the response from the dealer,
contact the Customer Service Department:  Champion Cooler, 5800 Murray Street, Little Rock, Arkansas 72209.  1-800-643-8341.  E-mail:
[email protected]

This limited warranty applies to original purchaser only.

Replace Aspen Pads (RLD Models). 

 The aspen pads should be

replaced once or twice a season, depending upon the length of the
season.  A new clean pad is more absorbent and efficient and will
deliver substantially cooler air.

Clean/Replace Filters (RLD2 Models).

  The RLD2 models have

an efficient rigid media which lasts 3-5 times longer than aspen.
Annually or more frequently depending on water conditions, these
filters will need to be cleaned.  The use of a bleed off will help
decrease the buildup of deposits on the pads.  To clean, remove the
filters and use a scrub brush to loosen heavy deposits.  Loose dirt
and debris can be removed by shaking the dried pad.    Rinse out the
bottom of the cooler and the pads and put them back into the cooler.
We recommend replacing these pads every 3 years depending on
the quality of your water.  Remember, a clean pad is more absorbent
and efficient and will deliver cooler air.  

Note:  Do Not use harsh

chemical cleaners - this will void your pad warranty.

Check bleed-off valve to be sure
it is not clogged.

Check belt tension.

  A 3 lb. force

should deflect the belt 3/4 inches (see
Fig. 10).  Readjust belt if needed.

Clean pump.

  Cleaning the pump is necessary once a year at start-

up.  For your safety, turn unit off and unplug motor and pump.
Remove the pump from the mount slot.  Remove the base of the
pump as shown in Fig. 11.  Clean the pump and turn the impeller to
ensure free operation.  Remove the pump spout and check for any

blockage.  After cleaning, rein-
stall the base onto the pump.
Reattach the pump to the mount
in the cooler using the plastic re-
tainer to ensure that the pump
will not overturn.  Do not forget
to replace the spout and water
delivery tube onto the pump
outlet.  The pump has an auto-
matic reset thermal protection.

Winter Shut Down

Drain water. 

 Always drain all of the water out of the cooler and

water supply line when not in use for prolonged periods, and par-
ticularly at the end of the season.  Keep the water line disconnected
from both the unit and water supply so that it does not freeze.

Unplug motor and pump.

  When cooler is not used for extended

periods, unplug the motor and pump from inside cooler.

Cover unit. 

 To protect the life of the finish, a cover for the unit is

suggested in extended periods of non use.

By following the operating, installation, and maintenance suggestions
as outlined, you can get many years of efficient and satisfactory
service from your cooler.  In the event additional information is de-
sired, your dealer will be more than glad to assist you in every possible
way.

Fig. 10

3 Lb.

3/4 Inches

Depress Here To

Remove

Fig. 11

Summary of Contents for 3000RLD

Page 1: ... this fan with any solid state fan speed control device Read And Save These Instructions Vea El Español En El Interior 110524 3 05 Models 3000RLD 3001 RLD2 4000RLD 4001 RLD2 5000RLD 5001 RLD2 www championcooler com C H A M P I O N EVAPORATIVE COOLER Owner s Manual Evaporative Cooling Evaporative cooling is nature s way of cooling When air is moved over a wet surface water is evaporated and heat is...

Page 2: ...wide in each room that you want to cool 4 Take the piece of tissue paper and put it up against the screen of the open window furthest from the cooler discharge opening Let go of it It will do one of three things IF It falls down THEN CLOSE all of the windows one inch and try step 4 again IF It plasters itself to the screen THEN OPEN all of the windows one inch and try step 4 again IF It stays on t...

Page 3: ...th an amperage meter Adjust pulley if necessary If amperage draw is less than motor rating turn off electrical power and remove pad frame Unplug motor inside cooler this will protect you from someone turning on unit while you are working inside This should be done for your safety Adjust pulley to a larger diam eter and readjust belt tension plug motor in install pad frame and retest amperage draw ...

Page 4: ...ch lasts 3 5 times longer than aspen Annually or more frequently depending on water conditions these filters will need to be cleaned The use of a bleed off will help decrease the buildup of deposits on the pads To clean remove the filters and use a scrub brush to loosen heavy deposits Loose dirt and debris can be removed by shaking the dried pad Rinse out the bottom of the cooler and the pads and ...

Page 5: ...Pads mildewed or clogged 3 Pads not wetting properly Trough holes clogged Pump not working properly 1 Float arm not adjusted properly 2 Overflow assembly leaking 1 Check power Replace fuse Reset breaker Plug in cords or replace if damaged 2 Adjust belt tension 3 Determine cause of overheating Adjust belt tension Oil blower bearings Adjust pulley to correct diameter 4 Replace motor 1 Open windows o...

Page 6: ... 23 Pump Screen Malla Para La Bomba 281001 001 281001 001 281001 001 24 Pump Assembly Bomba C60P 120 C60P 120 C60P 120 25 Pump Retainer Sujetador De La Bomba 110866N 110866N 110866N 26 Connector Pump Mount Unión Para La Montura De La Bomba 3PM 1 3PM 1 3PM 1 27 Float Bracket Soporte Del Flotador 216001 003 216001 003 216001 003 28 Tube Water Delivery Tubo De Agua 310716 310716 310716 30 Over Flow A...

Page 7: ...3001 RLD2 1 3 139 206 29 3 16 34 1 8 34 1 8 13 5 8 13 5 8 1 2 140 207 4000 RLD 4001 RLD2 1 3 174 257 30 11 16 39 39 17 3 4 17 3 4 1 2 175 258 3 4 179 262 5000 RLD 5001 RLD2 1 2 224 316 37 11 16 41 1 4 41 1 4 19 3 4 19 3 4 3 4 228 320 1 235 327 Motor weight is included Incluye el peso del motor General Specifications Especificaciones Generales 27 24 9 8 25 20 14 26 3 42 2 3 8 7 30 15 4 6A RLD2 21 2...

Page 8: ...os no use este ventilador con ningún dispositivo de estado sólido para controlar la velocidad del ventilador Funcionamiento Para el mejor funcionamiento si los filtros son secos prenda sólo la bomba durante unos cuantos minutos antes de prender el motor del ventilador Su unidad puede ser utilizada sin agua para proporcionar ventilación solamente Cuando hace fresco por ejemplo de noche o cuando la ...

Page 9: ... cuadradas de abertura 3466 1000 2 6 9 Ahora multiplique el número de las ventanas por el ancho de las mismas luego divida esta cantidad entre el número de pulgadas cuadradas requeridas para su unidad El resul tado le dice hasta qué altura hay que abrir las ventanas En este ejemplo cuatro ventanas que miden 36 pulgadas 0 9 m de ancha se deben abrir 6 9 pulgadas por cada una El Metodo De Equilibrar...

Page 10: ...itan ser lubricados Estos motores son lubricados en la fábrica de por vida y no requieren nunca ninguna lubricación PRECAUCION No lubrique demás El agregar demasiado aceite puede ocasionar que se queme el motor a causa del aceite entrando al interior del motor Compruebe la tensión de la co rrea Una fuerza de 3 libras debe desviar la correa 3 4 pulgadas véa se fig 9 Ajuste la correa si es necesario...

Page 11: ...elación con este producto Términos y Condiciones De La Garantía Al partir de la fecha de compra reemplazaremos cualquier componente original proporcionado por Champion Cooler que falle debido a cualquier defecto de material o mano de obra en la fábrica como el sigiente Ocho años por la base original del enfriador si gotea agua debido a oxidación Dos años por los filtros rigidos Modelos RLD2 solame...

Page 12: ...mplace el cable 2 Ajuste la tensión de la correa 3 Determine la causa Ajuste la tensión de la correa Lubrique los cojinetes Ajústela al diámetro correcto 4 Cambie el motor 1 Abra las ventanas o las puertas para aumentar el flujo de aire 2 Ajuste la tensión o cambie la correa 3 Cambie los filtros 4 Limpie el sistema de distribución y los agujeros del canal 1 Abra más las ventanas o puertas 2 Revise...

Reviews: