Installation

NOTE:

  The pump and float are installed in the cabinet.  The belt is

shipped inside the cabinet and the motor pulley kit and motor are
shipped separately.

CAUTION:

  Make sure that the mounting surface is strong

enough to support the operating weight of the cooler when in
use.  (For operating weight, see Specification Table.)

CAUTION:

  Never plug in cooler until installation is com-

plete and unit has been tested for rigidity.

Motor Installation

Install motor cord.

  For typical 120V operation, connect motor

cord to motor using the following color code:  Black - Hi, Red - Low,
White - Com., Green - Ground.  (See Wiring Diagram).

Mount motor.  

Install blower motor in the motor mount yokes,

adjusting the yoke if necessary.  Fasten with the provided mounting
clips (see Fig. 1).

Install pulley.

  Install the adjustable motor pulley so that it aligns

with the blower drive pulley (see Fig. 2) and tighten set screw.

Motor
Clips

Adjustable
Yoke

Fig. 1

Blower

Housing

Motor
Pulley

Blower
Pulley

Fig. 2

Open Windows To Exhaust Air

An often misunderstood concept of evaporative cooling is the amount
of air that should be exhausted.  How much should you open your
windows?  The fact is that most people do not open their windows
enough.  The following two methods will help you determine the
amount to open your windows.

CFM Method

You should allow an opening of at least 2 square feet (288 square
inches) for each 1000 CFM rating of your unit.  

Example:

  At 3466

CFM, model 4001 RLD2 with a 1/2 Hp requires 6.9 square feet (998
square inches) of opening  (3466/1000 * 2 = 6.9).  Multiply the
number of windows by window width in inches and divide this into
the number of square inches required for your size unit.  This will give
you the height to open windows.  In this example, four 36 inch wide
windows should be opened 6.9 inches each.

Champion Air Balancing Method

1. Take a piece of tissue paper and cut it lengthwise into 3 equal

strips.

2. Turn your cooler on high cool.

3. Open one window at least six inches wide in each room that you

want to cool.

4. Take the piece of tissue paper and put it up against the screen of

the open window furthest from the cooler discharge opening.  Let
go of it.  It will do one of three things.

IF

It falls down.

THEN

CLOSE all of the windows one inch and try step 4 again.

IF

It plasters itself to the screen.

THEN

OPEN all of the windows one inch and try step 4 again.

IF

It stays on the screen lightly.

THEN

PERFECT.  You are done.  Enjoy your cooler.

NOTES:

• When switching to low cool, you must rebalance your home.  Re-

peat step 4.

• Once you balance your home you can cool some areas more than

others by opening those windows more and closing the others by
the same amount.  Repeat step 4 to make sure your home is still air
balanced.

Screws

Fig. 3

Junction Box

Electrical Installation

WARNING:

  Disconnect all electrical service that will be

used for this unit before you begin the installation.

Remove junction box.

The electrical junction
box is located in the up-
per inside corner of the
cooler cabinet.  Remove
the two screws and slide
cover down for access to
plug wiring (Fig. 3).

Hook up electrical.

  Electrical hook up should be done by a quali-

fied electrician, so that all electrical wiring will conform to your
local standards.  This unit is supplied with a 120V pump.  For
240V pump operation, a 240V pump must be purchased.  The fan
and pump receptacles will support  both 120V and 240V installa-
tions.  See the following wiring diagrams for 120V and 240V
installations.

IMPORTANT:

  When a single speed motor is used, do not use the

red lead on the receptacle and motor plug wiring.  Tape off end of
both of the red leads.

WARNING:

  Make sure that cooler cabinet is properly

grounded to a suitable ground connection for maximum safety.

Operation

For the best cooling performance, if the pads are dry, pre-wet the
pads by running the pump for a few minutes before starting the
blower.

These coolers may be used without water for ventilation purposes.
When outside air is cool (for example, at night) or when humidity is
high, the water pump can be turned off.

A cooler can also be installed with a thermostat and attic exhaust
dampers to provide completely automatic operation.

Summary of Contents for 3000RLD

Page 1: ... this fan with any solid state fan speed control device Read And Save These Instructions Vea El Español En El Interior 110524 3 05 Models 3000RLD 3001 RLD2 4000RLD 4001 RLD2 5000RLD 5001 RLD2 www championcooler com C H A M P I O N EVAPORATIVE COOLER Owner s Manual Evaporative Cooling Evaporative cooling is nature s way of cooling When air is moved over a wet surface water is evaporated and heat is...

Page 2: ...wide in each room that you want to cool 4 Take the piece of tissue paper and put it up against the screen of the open window furthest from the cooler discharge opening Let go of it It will do one of three things IF It falls down THEN CLOSE all of the windows one inch and try step 4 again IF It plasters itself to the screen THEN OPEN all of the windows one inch and try step 4 again IF It stays on t...

Page 3: ...th an amperage meter Adjust pulley if necessary If amperage draw is less than motor rating turn off electrical power and remove pad frame Unplug motor inside cooler this will protect you from someone turning on unit while you are working inside This should be done for your safety Adjust pulley to a larger diam eter and readjust belt tension plug motor in install pad frame and retest amperage draw ...

Page 4: ...ch lasts 3 5 times longer than aspen Annually or more frequently depending on water conditions these filters will need to be cleaned The use of a bleed off will help decrease the buildup of deposits on the pads To clean remove the filters and use a scrub brush to loosen heavy deposits Loose dirt and debris can be removed by shaking the dried pad Rinse out the bottom of the cooler and the pads and ...

Page 5: ...Pads mildewed or clogged 3 Pads not wetting properly Trough holes clogged Pump not working properly 1 Float arm not adjusted properly 2 Overflow assembly leaking 1 Check power Replace fuse Reset breaker Plug in cords or replace if damaged 2 Adjust belt tension 3 Determine cause of overheating Adjust belt tension Oil blower bearings Adjust pulley to correct diameter 4 Replace motor 1 Open windows o...

Page 6: ... 23 Pump Screen Malla Para La Bomba 281001 001 281001 001 281001 001 24 Pump Assembly Bomba C60P 120 C60P 120 C60P 120 25 Pump Retainer Sujetador De La Bomba 110866N 110866N 110866N 26 Connector Pump Mount Unión Para La Montura De La Bomba 3PM 1 3PM 1 3PM 1 27 Float Bracket Soporte Del Flotador 216001 003 216001 003 216001 003 28 Tube Water Delivery Tubo De Agua 310716 310716 310716 30 Over Flow A...

Page 7: ...3001 RLD2 1 3 139 206 29 3 16 34 1 8 34 1 8 13 5 8 13 5 8 1 2 140 207 4000 RLD 4001 RLD2 1 3 174 257 30 11 16 39 39 17 3 4 17 3 4 1 2 175 258 3 4 179 262 5000 RLD 5001 RLD2 1 2 224 316 37 11 16 41 1 4 41 1 4 19 3 4 19 3 4 3 4 228 320 1 235 327 Motor weight is included Incluye el peso del motor General Specifications Especificaciones Generales 27 24 9 8 25 20 14 26 3 42 2 3 8 7 30 15 4 6A RLD2 21 2...

Page 8: ...os no use este ventilador con ningún dispositivo de estado sólido para controlar la velocidad del ventilador Funcionamiento Para el mejor funcionamiento si los filtros son secos prenda sólo la bomba durante unos cuantos minutos antes de prender el motor del ventilador Su unidad puede ser utilizada sin agua para proporcionar ventilación solamente Cuando hace fresco por ejemplo de noche o cuando la ...

Page 9: ... cuadradas de abertura 3466 1000 2 6 9 Ahora multiplique el número de las ventanas por el ancho de las mismas luego divida esta cantidad entre el número de pulgadas cuadradas requeridas para su unidad El resul tado le dice hasta qué altura hay que abrir las ventanas En este ejemplo cuatro ventanas que miden 36 pulgadas 0 9 m de ancha se deben abrir 6 9 pulgadas por cada una El Metodo De Equilibrar...

Page 10: ...itan ser lubricados Estos motores son lubricados en la fábrica de por vida y no requieren nunca ninguna lubricación PRECAUCION No lubrique demás El agregar demasiado aceite puede ocasionar que se queme el motor a causa del aceite entrando al interior del motor Compruebe la tensión de la co rrea Una fuerza de 3 libras debe desviar la correa 3 4 pulgadas véa se fig 9 Ajuste la correa si es necesario...

Page 11: ...elación con este producto Términos y Condiciones De La Garantía Al partir de la fecha de compra reemplazaremos cualquier componente original proporcionado por Champion Cooler que falle debido a cualquier defecto de material o mano de obra en la fábrica como el sigiente Ocho años por la base original del enfriador si gotea agua debido a oxidación Dos años por los filtros rigidos Modelos RLD2 solame...

Page 12: ...mplace el cable 2 Ajuste la tensión de la correa 3 Determine la causa Ajuste la tensión de la correa Lubrique los cojinetes Ajústela al diámetro correcto 4 Cambie el motor 1 Abra las ventanas o las puertas para aumentar el flujo de aire 2 Ajuste la tensión o cambie la correa 3 Cambie los filtros 4 Limpie el sistema de distribución y los agujeros del canal 1 Abra más las ventanas o puertas 2 Revise...

Reviews: