4
Safety Re
v
ersing
Sensor
Header
W
all
Access Door
— — — — — — — —
Gap
b
et
w
een floor
and
b
ottom of door
m
u
st not exceed 1/4" (6 mm).
Extension Spring
Horizontal and
v
ertical reinforcement
is needed for light
w
eight garage doors
(fi
b
erglass, steel, al
u
min
u
m, door
w
ith
glass panels, etc.). See page 23 for details.
S
u
pport
b
racket &
fastening hard
w
are
is re
qu
ired.
See page 16.
FI
N
ISHED CEILI
N
G
Motor Unit
Rail
W
all-
mo
u
nted
Door
Control
OR
Torsion Spring
Vertical
Centerline
of Garage
Door
Safety Re
v
ersing
Sensor
SECTIONAL DOOR INSTALLATION
Planning
Identify the type and height of your garage door.
Survey your garage area to see if any of the
conditions below apply to your installation. Additional
materials may be required. You may find it helpful to
refer back to this page and the accompanying
illustrations as you proceed with the installation of
your opener.
Depending on your requirements, there are several
installation steps which may call for materials or
hardware not included in the carton.
• Installation Step 1 – Look at the wall or ceiling
above the garage door. The header bracket must
be securely fastened to structural supports.
• Installation Step 5 – Do you have a finished ceiling
in your garage? If so, a support bracket and
additional fastening hardware may be required.
• Installation Step 10 – Depending upon garage
construction, extension brackets or wood blocks
may be needed to install sensors.
• Installation Step 10 – Alternate floor mounting of
the safety reversing sensor will require hardware
not provided.
CLOSED POSITION
Header
W
all
Garage
Door
Header
Bracket
Trolley
Straight
Door
Arm
Emergency Release
Rope & Handle
Door
Bracket
C
u
r
v
ed
Door
Arm
Garage
Door
Spring
Belt
Trolley
Stop Bolt
• Do you have an access door in addition to the
garage door? If not, Model 7702C Emergency Key
Release is required. See Accessories page.
• Look at the garage door where it meets the floor.
Any gap between the floor and the bottom of the
door must not exceed 1/4" (6 mm). Otherwise, the
safety reversal system may not work properly. See
Adjustment Step 3. Floor or door should be
repaired.
SECTIONAL DOOR INSTALLATIONS
• Do you have a steel, aluminum, fiberglass or glass
panel door? If so, horizontal and vertical
reinforcement is required (Installation Step 11).
• The opener should be installed above the center of
the door. If there is a torsion spring or center
bearing plate in the way of the header bracket, it
may be installed within 4 feet (1.22 m) to the left or
right of the door center. See Installation Steps 1
and 11.
• If your door is more than 7 feet (2.13 m) high, see
rail extension kits listed on Accessories page.