CGEO-PR-VW Vibrating Wire Portable Readout
CGEO INTERNATIONAL LIMITED
Installation Manual
Press “
▲”
or
“▼”
to select this
screen, then press “
” to start and
operate “Timing Turnoff”. The information is stored in SRAM. Then the
system returns to the main menu.
Note:
1) “Timing Turnoff” is imperative and should be enabled
2) After setting, the system will turn off in 15m automatically
4.02.6
Data View
All data stored can be viewed.
When you select the Data View Page, the following screen will be displayed:
The information shown includes the current Page-Box No.-Channel No.
Model A F Modulus F² or frequency, Unit: Hz² and Temperature °C or resistance, Unit:
Ω. If the mode is “Frequency and Resistance”, the display information is: Frequency:
******. **Hz, Resistance *****Ω.If the mode is “Modulus and Temperature”, the display
information is: Modulus ******.*F,
Temperature ****°C. (Note: If the used temperature sensor is not from CGEO
there may be some error.
If the selected screen is empty or has been deleted, in “Frequency and
Resistance” Mode the display is: Frequency: -------Hz, Resistance: ----Ω; or
Summary of Contents for CGEO-PR-VW