5.5.3
TIME-MASTER
With the TIME-MASTER, you set the opening time of the IES.
During the opening time, your IES allows free access.
When the IES detects the TIME-MASTER, it starts beeping at
one-second intervals. The number of beeps determines the
opening time.
5.5.4
RELEASE-MASTER
With the RELEASE-MASTER, you can set the IES into enable
condition. In enable condition, no locking media are read and
the IES allows permanent free access.
5.5.5
BLOCK-MASTER
With the BLOCK-MASTER, you can set your IES into blocked
condition. In blocked condition, all locking media are rejected.