3-5
14.
For a Battery Discharge, proceed as follows:
BATTERY DISCHARGE
ACTION
CHECK
NOTES
1. Alternator switch
Ensure ON
2. Alternator and Alternator Field
Circuit Breakers
Ensure IN
If discharge continues:
1. Alternator Switch
Cycle OFF, then ON
To reset over-voltage sensor.
If discharge continues:
1. Alternator Switch
Select OFF
2. Unnecessary electrics
Select OFF
3. Battery voltage
monitor
Available power highly
dependent on battery condition,
charge and electrical services
selected.
4. Land
As soon as practicable
Reduce all available electrical
load, in order to conserve power
for EDM930 operation, circuit
and landing.
Figure 3-4 Battery Discharge Alerts
NOTE
Battery power is sufficient for normal (VFR) operations for a
minimum of 30 minutes.
CAUTION
Total electrical failure will result in the loss of all engine instrument
indications on the EDM-930 display. Should this occur, avoid high
power settings, avoid rapid power changes and enrich the mixture
to maintain smooth engine operation.
Summary of Contents for 182