3.4.3. Weather forecast
If the CM-WiFi box is connected to the Internet and the correct address of the installed boiler is
entered in the web portal, there is below the measured room temperature a weather forecast for the
place where the CM-WiFi box with the currently read temperature from the server (with the date
and hour of reading the current temperature and forecast) and the weather forecast for today
appears and for the next four days (with a minimum and maximum daily temperature). If the CM
WiFi box is not connected to the Internet, the current forecast will not be displayed on the screen.
Then it is recommended to turn off the weather forecast and it will not longer be displayed on the
screen.
Weather forecast
ON
Factory:
setting
OFF / ON
3.7. Shutdown
The Digital Room Concealer is intended for year-round use, ie room temperature measurement. If
you want to turn off the corrector completely (because it will not be used or want to save electricity
when we do not intend to use corrector), pressing the OK button will completely off the corrector.
When you want to restart the room corrector, you need to press the screen for a few seconds until a
beep sounds and the corrector lights up and starts working on the last view before shutting down.
3.5.2. Sound type
Select one of ten sound types offered when you
press the screen or an error / warning occurs.
3.5. Sound
3.5.1. Sound volume
Adjusting one of three preset volume levels
or muting completely when a button is displayed on the
screen and when an error / warning occurs.
3.6. Info
Information on the version of the software entered in the corrector.
3.8. Load factory
Load the factory settings of the room corrector. After that, the room corrector must be reconfigured.
3.4.4. Screensaver
After a certain screen idle time, the screen saver is turned off to reduce power consumption and
extend the screen life. The screen saver works in two levels: after
Time 1
, the backlight intensity
decreases, and after
Time 2
has elapsed, the measured room temperature of the selected view and
the current clock will change on the screen. By tapping the screen, the screen saver turns off.
3.4.4.1. Backlight
The backlight intensity after
Time 1
has elapsed, ie. when the screen saver turns on.
3.4.4.2. Time 1
Time that starts to run after the last touch on the
screen (after which the screen saver is turned on).
3.4.4.3. Time 2
Time that begins to flow after
Time 1
has passed
(in
Time 2
the
Backlight
intensity decreases and after
that time, only the current room temperature / current clock starts to appear on the screen.
Backlight
20
Factory:
min./max.
5 / 50
uni.
Time 1
60
10 / 600 sec
%
Time 2
10
0 / 720
min
Sound volume
3
Factory:
setting
OFF / 1/2/3
Sound type
Type 6
Factory:
setting
Type 1...Tip 10
Settings