2.x.x. Pellets (only with BioTec Plus)
2.x.1. Buffer tank temp.
Default buffer tank temperature
2.x.2. Min buf. tank temp.
Default minimum buffer tank temperature
2.x.3. Diff. buf. tank temp.
Default differential to start warming up the
buffer tank
2.x.4. Diff. stop buff. tank
Default differential to turn OFF warming up the AKU. tank
Buffer tank temp.
80
Factory
min./max.
40 / 80 °C
Min buf. tank temp.
20
5 / 85 °C
Diff. buf. tank temp.
10
5 / 30 °C
Dif. stop buff. tank
5
3 / 30 °C
3. BOILER (ONLY WITH BioTec-L AND BioTec Plus)
BioTec-L
BioTec Plus
3.1. Glow
The Glow option retains the glow in the upper
firebox of the boiler (it shuts down ventilator a little
earlier than in the option without maintaining the
glow) so that the next time you can continue
working faster with newly added fuel, without the
need for new ignition (only with "Wood"). For more
information see:
Technical instructions for
BioTec Plus or BioTec-L
Factory:
ON
setting:
OFF / ON
3.2. Taking over (only with BioTec Plus)
„Taking over” option is used for automatic
switching operation from wood to pellets.
Automatic switching is only possible from "Wood"
to "Pellets". For more information see:
Technical
instructions for BioTec Plus
Factory:
OFF
setting:
OFF / Pellet ON
3.3. Boiler side (only with BioTec Plus)
Factory:
-
It is possible to switch from wood to pellets and
then remotely turn on the pellet boiler. After typing
on boilers touch screen, this optin on CSK-Touch
is blocked for the next 5 minutes.