Configuring a wireless connection of the corrector via a HOME ROUTER:
3.1.1. Connection type
->
Home router
3.1.2. WiFi network name
-> it is necessary to enter the correct name of the network (pay attention
to uppercase and lowercase letters) to which the corrector is connected.
3.1.3. WiFi password
-> it is necessary to enter the correct password of the network (pay attention
to uppercase and lowercase letters) to which the corrector is connected.
3.1.4.WiFi ID
-> rewrite it from the table on the boiler controller (Image: table on the boiler controller)
3.1.5. Address code
-> rewrite it from the table on the boiler controller
- IMPORTANT - the address code must be the same as selected corrector address!
3.1.6. Corrector address
-> check that the same address is selected as on the boiler - if not, the
correct Address Code is not entered in the corrector.
3.1.7. Get data
-> START – if everything is configured correctly, the corrector will be connected to
the boiler / CM2K module (symbol in the upper right corner of the screen) and data from the boiler
control can be downloaded. If the corrector is not connected to the boiler / CM2K module, the
download will not be possible and you should check the correctness of the data entered.
After successful download of data from the boiler, it is necessary in menu
3.2. VIEWS
join each
view of the corrector to each heating circuit and add a name if you want. If there is only one room
corrector in the heating system, in menu 3.2.1. Number of views is selected number 1. If there are
several room correctors (digital or analog) that you want to monitor/manage with this corrector, the
number of all correctors you want to monitor must be selected in this menu. Depending on the
number of selected views, in menu 3.2. Views the same number of button for editing a single view
appears (eg 3 views, View button A, B, C). In menu 3.2.2. View A can change the name of that view
(factory A) to eg 1st Floor or Living Room… (max. 30 symbols) and in the menu
3.2.2.2. Heating
circuit
be sure to select the heating circuit to which that corrector joins.
After setting these basic parameters, the corrector is ready for use.
42dB
Wired
Router
209
1 3
Addr. 1
38dB
153
427
1
2
3
4
5
6
7
8
Image: table on the boiler controller
(only for authorized service persons)
;
Installation
->
PIN
->
CSK-Touch
->
Info
.
1. WiFi ID uniquely generated (or taken from WiFi-box)
2. CSK-Touch address on the boiler
3. Add. code uniquely generated by the boiler for each add.
4. Corrector connection type with CM2K / boiler
5. Visibility of CSK-Touch
6. Signal quality
7. No. of packets downloaded from boiler controller