7
ENGLISH
When ordering spare parts always specify the following:
- code number of item.
- name of item.
- type of tool.
- tool serial number.
6. WARNING
The press is robust and does not require special attention; to obtain correct operation it is suffi
cient
to observe a few simple precautions:
6.1) Accurate cleaning
After each day’s use clean the press with a clean cloth, to remove dust and dirt particles.
6.2) Storage
When not in use, store the press in a clean, dry area and protect it from dust and accidental demage.
6.3) Control pedal
The fl exible pipes must not be twisted or constricted.
7. MAINTENANCE
(Ref. to Fig. 1)
Lubricate the six pivot pins (58) and (61) every 12 months, which ever is earliest, as follows:
– Disconnect the air supply from the press;
– Disconnect the control pedal;
– Remove the six screws (34) holding the housing (06) to the base (72);
– Unscrew the air supply coupling (22);
– Unscrew the knurled knob (10);
– Lift and remove the housing and remove the guard (60), lubricate the pivot pins;
– Refi t the guard, the housing, the coupling and the knob.
After each maintenance operation always check that the machine guards are correctly position.
8. RETURN TO
Cembre
FOR OVERHAUL
In the case of a breakdown contact our Area Agent who will advise you on the problem and give
you the necessary instructions on how to dispatch the tool to our nearest service Centre; if possible,
attach a copy of the Test Certifi cate supplied by
Cembre
together with the tool or fi ll in and attach
the form available in the “ASSISTANCE” section of the
Cembre
website.