5
ENGLISH
3.1.2) Setting up the press to compress terminals insulated with YELLOW PVC OR PC and RED
BLUE and YELLOW disconnect terminals partially or fully insulated with PC or PA6.6
Check the position of the knurled stop (10); it must be
completely extracted
with the yellow band
visible, out of the housing; if this is not the case, press the control pedal (02) and at the same time
pull the knurled stop out as far as it will go.
To adjust the positioning device refer to § 4.
The press is now ready for use; to make the connec-
tion; introduce the terminal, placed on the end of the conductor, into the appropriate aperture in
the head and depress the pedal.
3.2) PNB-3PD PNB-3N1 PNB-3NN3 PNB-3N5 PNB-3NN4 PNB-3F/M
Presses
Check the position of the knurled stop (10); it must be
completely extracted
with the yellow band
visible, out of the housing; if this is not the case, press the control pedal (02) and at the same time
pull the knurled stop out as far as it will go.
The press is now ready for use; to make the connection; introduce the terminal, placed on the end
of the conductor, into the appropriate aperture in the head and depress the pedal.
4. INSTRUCTIONS FOR USING THE POSITIONING DEVICE
LOCATED ON THE PNB-3P PRESS
(Ref. to Fig. 2, Page 25)
Before using the press it is necessary to make the adjustments to suit the range of terminal to be
compressed, (Refer to TABLE 1 page 26).
4.1) PVC and PC insulated crimp terminals
(ring, fork, pin and blade)
Slightly slacken the knob (105) lower stop (104) all the way down and leave the knob slackened.
Introduce the terminal, placed on the end of the conductor, into the appropriate aperture until the
coloured sleeve butts against the stop (104) and depress the pedal.
4.2) Female and male disconnect terminals partially or fully insulated with PC or PA6.6
Slightly slacken knob (105), raise stop (104) to the upper limit and lock in position by tightening
the knob.
Choose the scale position depending on the type of connector to compress by consulting
TABLE 1
;
slacken the grub screw (106) situated on the upper part of the positioning device turn the reference
symbol to the desired position (refer to table 1) and retighten grub screw (106).
Introduce the terminal, placed on the end of the conductor, into the appropriate aperture, up to
the stop and depress the pedal.