4
WARNING
Do not use the tool for purposes other than those intended by
Cembre
.
The operator should concentrate on the work being performed and be careful to
maintain a balanced working position.
Before starting work on electrical equipment, please ensure that either there are
no live parts in the immediate working area or that precautions are taken for
working near live parts in accordance with EN50110-1.
Do not use this tool on or near energised conductors without proper personal
protective equipment. Failure to observe this warning could result in severe injury
or
death.
1. GENERAL CHARACTERISTICS
Application range
suitable for installing electrical compression connectors
for conductors up to 300 mm² (600 MCM)
Rated force
kN (US sh. ton)
64 (7.2)
Operating pressure
bar (psi)
725 (10,515)
Dimensions
mm (inches)
380x130 (14.9x5.1)
Weight
kg (lbs)
2,75 (6)
Recommended oil
ENI ARNICA ISO 32 or equivalents
Operating speed
twin speed operation and automatic switching from
a rapid advancing speed of the ram to a slower,
more powerful working speed
Safety
maximum pressure valve
2. INSTRUCTIONS FOR USE
2.1) Preparation
Select the appropriate die set for the connector.
Open the latch (1) and release the upper die holder (6) (Ref. to Fig. 1).
Insert one die into the upper die holder (6) until locked by the ball (8) and one die into
the lower die support (2) until locked by the spring clips (9) (Ref. to Fig. 1).
Close the head.