20
ENGLISH
5.2) Rucksack
To protect the pump from accidental damage and dust, it should be stored with its accessories in
the special rucksack provided and sealed well.
Rucksack
type CVB-037
: Size 540x270xh550 mm (21.2x10.6x21.6 inches), weight 3,2 kg (7 lbs).
5.3) Storage
Once the job has been
completed always completely release the pressure
of the oil by holding
down the release button; ensure that the ram of the connected hydraulic head is completely
retracted before disconnecting the head.
Remove the battery from the pump.
Disconnect the remote controller.
Disconnect the fl exible hose; avoid it becoming folded with narrow bends or knots that may
compromise its integrity.
Store the pump and accessories in the rucksack in a dry place.
5.4) Topping up the oil
(Ref. to Fig. 7)
Periodically check, at least every 6 months, the oil level in the pump and top up if necessary:
Position the pump on its base on a fl at surface.
Completely discharge the oil pressure by pushing the pressure release button (7).
Unscrew the fi ller cap (2).
By using a funnel,
top up very slowly
to completely fi ll the oil reservoir to the maximum level.
When the operation is fi nished replace the cap (2).
Always use clean recommended oil, see § 1.
Do not use old or recycled oil. Do not use hydraulic brake fl uid.
Ensure that used oil is disposed of in accordance with current legislation.
6. CONNECTION TO COMPUTER
(Smartool technology)
Extract the battery and connect the supplied USB cable to the connector (30) inside the battery
seat then to the USB port of the PC (Ref. to Fig. 9).
The memory card integrated in the tool records operating data for transfer via the USB cable supplied.
To view and manage this data, go to
www.cembre.com
and register in the dedicated area, then
download the free
Cembre
software
CEM_SWBT01
.
Keeping the Firmware of the tool updated, via free of charge download from here, will optimise
the tool's performance.