12
ENGLISH
11
CONTROL BUTTON ON THE PUMP
:
rocker type switch, allows:
To switch on the pump (push forwards for actuation, starting with display off ).
To control the pump (push forwards for actuation of the motor and backwards for oil re-
lease).
To control the pump from the button (11), it is necessary to deactivate the ERCH push-
button panel via the display (see § 4.4 for further details).
When a crimping head is used, press and hold the operating button (1) until the motor
stops
automatically.
AUTO POWER-OFF: the pump switches off automatically after a period of inactivity
of 5 minutes; to reactivate the pump, press the button again.
12
TRANSPORT HANDGRIP
3. INSTRUCTIONS FOR USE
3.1) Preparation
The pump can be easily carried using either the main handle (10) or the shoulder strap attached
to the two rings (1) (Ref. to Fig. 2).
Position the pump on a fl at surface. There are two stable work positions recommended (see Fig. 6):
- vertical,
resting on its base.
- horizontal,
resting on its back where moulded ribs improve fi rmness and stability
Should it be necessary however, the pump’s hermetically sealed hydraulic circuit allows it to
operate in any position.
Before starting any work, check the battery charge and recharge it if necessary following
the instructions in the battery charger user manual.
3.2) Connecting the remote hand controller
(
Ref. to Fig. 4)
Remove "
REMOTE CONTROLLER
" protective cap, connect the remote hand controller to the
socket (10) (see Fig. 4): tighten the plug (16) by turning the bezel clockwise until it locks.
3.3) Connecting the fl exible hose
(
Ref. to Fig. 5)
Fully unravel the flexible hose.
Connect the male coupler (20) of the flexible hose to the female coupler (9) of the pump then
pull towards the hose and turn the safety ring (G) to eliminate any risk of accidental disconnec-
tion.
Connect the female coupler (21) of the flexible hose to the male coupler (22) of the hydraulic
head to be used then pull towards the hose and turn the safety ring (G) to eliminate any
risk of accidental disconnection.
Before using the pump always check the integrity of the fl exible hose and the quick couplers
making sure there are no abrasions, cuts, deformations or swellings.
5 min.