background image

 

 

Summary of Contents for E12 CLEO

Page 1: ......

Page 2: ...nfrared Beam Sensor 2 2 2 Indoor Passive Infrared Wide Angle Sensors 14 2 2 3 Mini Passive Infrared High Power Sensor 15 2 2 4 Universal Transmitter Door Guard 2 2 5 Seismic Transmitter 16 2 2 6 Dual...

Page 3: ...tions of the Cleo from their cell phones via SMS The Cleo Panel Kit comes complete with a 3 Amp Power supply and charger 7 Amp Battery 3 Amp Plug in Transformer GSM and 433 MHz Aerials The Cleo can be...

Page 4: ...y programmable remotely via the CellSecure programming software 1 1 Modes of Operation The following modes of operation can be used Away Mode Stay Mode Monitor Mode Away Monitor Mode Off Mode 1 1 1 Aw...

Page 5: ...the internal siren and the necessary SMS and telemetry signal Alarm Armed will be sent Deactivating Away mode Activate Off Mode See section 1 1 3 1 1 2 Stay mode Normally activated when retiring for t...

Page 6: ...n the mode the system was in before activating OFF mode If the E12 was in Away Mode the E12 will respond by sounding twice on the internal siren only if the system was not activated by a sensor while...

Page 7: ...by SMS The E12 will send a Monitor mode activated SMS Activating Monitor Mode Monitor mode can be activated by SMS key ring remote or keypad To activate by SMS send XXXXM to the E12 To activate by Ke...

Page 8: ...response company if connected If the E12 receives multiple Silent panic signals it will re send the Silent Panic SMS and telemetry signal The name of the person who activated Silent Panic will be incl...

Page 9: ...key pad Press the Memory button Mem followed by enter Reset by SMS Send XXXXr to the E12 where XXXX is one of the 4 digit numeric user passwords The E12 will respond with 6 beeps on the internal buzz...

Page 10: ...e GAS is enabled or not This is done with the following messages XXXXG1 GAS enabled XXXXG0 GAS disabled GAS can be manually triggered by using XXXXG9 at any time When the gas is triggered the E12 will...

Page 11: ...at a specified time each day to indicate that the system is still in operation This 24 hour test SMS can be disabled if necessary The time of day when the SMS is sent can be specified by the user Thi...

Page 12: ...telemetry outputs meaning that a signal will be sent automatically every time the alarm is switched on off triggered etc To set the outputs as telemetry outputs send XXXX to the panel via SMS where X...

Page 13: ...Sensors Low or High power E6 and E12 2 Indoor Passive Infrared Sensors High power E12 3 Mini Passive Infrared Medium power E12 4 Mini Passive Infrared Low power E6 5 Universal Transmitters Hi and Lo P...

Page 14: ...circumstances this could be more It is recommended that the sensor is used as a proximity sensor and not as a perimeter sensor Do not use this sensor open ended ALWAYS point towards a wall Figure 3 Ou...

Page 15: ...Infrared Wide Angle Sensors 2 2 4 Universal Transmitter Door Guard Low and High Power The Door guard DG is actually a universal transmitter with integral panic button and connections for a magnetic co...

Page 16: ...of equipment is tilted ideal for computers When the alarm is in away mode and the sensor is tilted a little bit only an SMS will be sent Tilting it more will result in an alarm condition In any other...

Page 17: ...left 40Watt external siren middle and indoor siren right 3 Programming the E12 Cleo For new installations Press and hold the Learn button on the E12 Cleo until the LED switches off 18 sec KEYRINGS AN...

Page 18: ...Panel the learn LED should switch on 7 Press the Learn button on the sensor and hold for 3 sec 8 The Control Panel Learn LED may switch off 9 The Control Panel Learn LED should flash and then stop 10...

Page 19: ...witch on 6 Press the Learn button on the sensor and hold for 3 sec 7 The Control Panel Learn LED may switch off 8 The Control Panel Learn LED should flash and then stop 9 To program this device to a z...

Page 20: ...r 2 to 3 seconds after you release the button 4 Press the learn button on the panel once and make sure the LED switches on and stays on 5 Press the Learn button on the sensor and hold for 3 sec 6 The...

Page 21: ...rd 1 Open up the device and check that LK2 is configured correctly Check that the battery is connected 2 Reassemble the unit and Press the Panic Button Check that the LED of the sensor comes on and st...

Page 22: ...unit and Press the Panic Button Check that the LED of the sensor comes on and stays on for 2 to 3 seconds after you release the button 3 Press the learn button on the panel once and make sure the LED...

Page 23: ...e unit and Press the Panic Button Check that the LED of the sensor comes on and stays on for 2 to 3 seconds after you release the button 3 Press the learn button on the panel once and make sure the LE...

Page 24: ...3 3 Removing Wireless Sensors from zones Wireless sensors can be removed from a zone by following this procedure 1 Switch the E12 to Off Mode 2 Enter the 6 digit master code press the program button f...

Page 25: ...button followed by enter The Program button light will switch off and the trouble button light will switch on The numbers already associated with a remote will also switch on 4 Press the key ring numb...

Page 26: ...ndicating that the zone will be active in Away Mode To deactivate a zone press the corresponding zone number button on the keypad The button light will switch off indicating that the zone will not be...

Page 27: ...ht up and all the active zones will light up If no zone buttons light up no wired zones are active in Monitor Mode To program a wired zone to be active in Monitor Mode press the corresponding zone num...

Page 28: ...for example will mean that user password 2 must be programmed in The selected number button will start to flash 4 Enter the 4 digit numeric password and press enter 5 To program the next password sta...

Page 29: ...put 1 Off Pulse Output 4 XXXXE9 Output 1 pulse Switch On and Off Enable Disable functions Information requests Enable Gas discharge XXXXG1 Auto Gas Enabled Disable Gas discharge XXXXG0 Auto Gas Disabl...

Page 30: ...Appendix A Wiring Diagram Figure 9 Wiring diagram for the E12 Cleo A 1...

Page 31: ...keypads to the E12 Figure B 1 E12 Cleo PC board showing the location of the keypad connectors and keypad terminating pins Keypad Terminator pins Figure B 2 E12 keypad PC board showing the location of...

Page 32: ...ed in parallel The keypad terminator pins must be connected for the two devices on the opposite edges of the connection and unconnected for the other devices Figures B 1 and B 2 shows the location of...

Page 33: ...s Settings used with E6 Door Guard Function Dipswitch setting 1 2 3 4 Learn 1 0 0 1 Trigger in away mode 0 1 0 1 Silent in any mode 0 0 1 1 Use the Learn function setting to learn the device into the...

Page 34: ...ee figure 9 for wiring on the panel s side A 1 Figure 11 Connecting a Normally Closed panic button or magnetic switch to the E12 for 24 hour monitoring Opening the switch will result in a notification...

Page 35: ...ation message only no alarm condition Zone n must be active in Away mode Also see figure 9 for wiring on the panel s side N C Magnetic Switch Figure 13 Connecting a Magnetic Switch to the E12 for norm...

Page 36: ...36 Figure C 4 Garrison Beam connection to the E12 Cleo A 3...