20
3.1.4. Mini Indoor Passive infrared sensor
RB4:
•
Connected
for
E6 panels.
•
Unconnected
for E12 and
E45 panels.
Learn button
Battery Connector
Dipswitch
1. For E12 and E45 panels, make sure that there is no LINK connected to RB4. For E6
panels, make sure that the 2 RB4 Pins are connected.
2. Connect the battery. The Connector can only go one way.
3. Press the Learn Button and check that the LED of the sensor comes on and stay’s on
for 2 to 3 seconds after you release the button.
4. Press the learn button on the panel once and make sure the LED switches on and
stays on.
5. Press the Learn button on the sensor and hold for 3 sec.
6. The Control Panel Learn LED may switch off.
7. The Control Panel Learn LED should flash and then stop.
8. To program this device to a zone follow the steps in section 3.2 of this document.
3.1.5. Mini Door Guard
1. Press the Panic Button and check that the LED of the sensor comes on and stay’s on
for 2 to 3 seconds after you release the button.
2. Press the learn button on the panel once and make sure the LED switches on and
stays on.