32
Pins Connected
Pins Connected
Figure B.3
Keypads connected to panel.
Two keypads can directly connect to the panel, using the connectors shown. To connect
more than 2 keypads to the panel, the keypads must be wired in parallel. The keypad
terminator pins must be connected for the two devices on the opposite edges of the
connection and unconnected for the other devices. Figures B.1 and B.2 shows the
location of the keypad terminating pins on the panel and keypad respectively. Figure
B.3 shows 4 keypads connected to a panel in two different formats. The keypad
terminating pins must be connected as shown in figure B.3.
B.2