1.  warranty.
2.  Proof of purchase of the Product in the form of a bill of sale, receipted invoice or serial number, which is 

evidence that the Product is within the Limited Warranty Period, must be presented by the End User to 

CellarCool in order to obtain limited warranty service. 

3.  This limited warranty is void if the factory applied serial number has been altered or removed from the 

Product.

4.  This limited warranty is voided if installed in an enclosure of insufficient design that does not follow the 

Product installation requirements stated herein and in the owner’s manual.

5.  Removing the rivets from the Product’s unit housing without prior authorization from CellarCool voids this 

limited warranty.  

6.  The End User must first contact CellarCool Customer Service by telephone (at 1-800-343-9463) prior to 

attempting service on any Product still under the limited warranty; else the limited warranty is voided. 

7.  This limited warranty does not cover Product being concealed by, but not limited to, vegetation, fabric, 

shelving, mud, snow, or dirt. Product must not be painted or limited warranty will be void.

8.  This limited warranty does not cover exposure to corroding environments such as, but not limited to, 

petroleum and gasoline products, cleaning solvents, caustic pool chemicals, and marine air.

9.  This limited warranty does not cover any cause not relating to Product defect.
10.  THE REPAIR OR REPLACEMENT OF THE PRODUCT AS PROVIDED UNDER THIS LIMITED WARRANTY IS THE 

EXCLUSIVE REMEDY OF YOU, THE END USER, AS WELL AS ANYONE ELSE IN THE CHAIN OF TITLE OF THE 

PRODUCT, DOES NOT START A NEW LIMITED WARRANTY TIME PERIOD, AND IS IN LIEU OF ALL OTHER 

WARRANTIES (EXPRESS OR IMPLIED) WITH REGARD TO THE PRODUCT. IN NO EVENT SHALL CellarCool BE 

LIABLE FOR INCIDENTAL, CONSEQUENTIAL, SPECIAL OR CONTINGENT DAMAGES FOR BREACH OF ANY 

EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT. THE IMPLIED WARRANTIES OF MERCHANTABILITY 

AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY EXPRESSLY DISCLAIMED.  Some states do not 

allow the exclusion or limitation of incidental or consequential damages, or allow limitations on how 

long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This limited 

warranty gives you specific legal rights, and you may have other rights, which vary from state to state.

11.  Failure of the End User to comply with all of the Product Installation Requirements, Maintenance 

Requirements and End User Requirements may, at CellarCool’s sole discretion, void this limited warranty.

12.  No one has any authority to add to or vary the limited warranty on this Product.

3. Product Installation Requirements:

A. Prior to installing a CellarCool Product, the End User must read the CellarCool Owner’s Manual and thereafter 

the End User must follow the required installation, use and maintenance procedures set forth by CellarCool in 

CellarCool’s Owner’s Manual. The Owner’s Manual is shipped with each Product and if another copy is needed, 

replacement copies can be downloaded from CellarCool’s website (www.cellarcool.com) or by contacting 

CellarCool directly for a new copy of the Owner’s Manual. 

B. It is highly recommended that the End User obtain the assistance of a wine storage professional.
C. Failing to address all of the variables associated with proper installation will cause the Product to operate 

incorrectly and limit both the Product’s ability to cool and the longevity of the Product itself.

D. The End User is responsible for all risks and costs of installation of the Product, including but not limited to 

all labor costs as well as cost of any additional parts required for the proper and complete installation of the 

Product.  The End User is responsible for all risks and costs of removing the Product if limited warranty work is 

required.

E.  The Product cannot operate at its optimum capacity if airflow is constricted by ducting or venting the exhaust 

side of the Product into a location with inadequate ventilation.

4. Maintenance Requirements

It is the End User’s responsibility to clean off any accumulated dust, lint, or other debris from the front and rear 

intake grills; failure to do this on a regular basis will restrict the airflow and may affect the Product’s ability to 

Summary of Contents for ACH 550

Page 1: ...ACH 033114 TECH OWNERS MANUAL...

Page 2: ...purpose in whole or in part without the written consent of CellarCool Every effort has been made to ensure that the information in this manual is accurate CellarCool is not responsible for printing o...

Page 3: ...You Start Unobstructed Airflow Active Humidity Option Overview Installing the ACH 550 Humidifier Humidistat Installation Installing the ACH 550 Humidifier Continued Installing the Drain Line Maintena...

Page 4: ...2 1 855 235 5271 QUICK REFERENCE GUIDE Wall Mounted ACH 550 Humidifier Front Side View Humidifier Rear Side View Top Access Panel Drain Line Connection Power Cord Humidistat Connection Water Port Mou...

Page 5: ...x 7 1 8 d x 8 3 16 h Power Consumption 0 2 amps 120V 60 Hz Weight lbs 9 dBA TBD Drainline 1 2 Humidistat Range 30 90 RH Humidistat Accuracy 1 Humidistat Adjustment Increments 1 Water Supply Feed Rate...

Page 6: ...oducts and the best possible customer service If you have any questions about your system please call us at 1 855 235 5271 or visit CellarCool com Using the Manual This Owners Manual is intended to as...

Page 7: ...it is correct Check that all factory options ordered are listed If any items listed on the packing slip do not match your order information contact CellarCool Customer Service immediately Check the B...

Page 8: ...esigned and constructed controlled rooms Hire a professional consultant with a valid contractor s license to build your controlled room that is well insulated If you encounter a problem with your Cell...

Page 9: ...r must be mounted at least 3 from the floor in order to achieve sufficient humidity Mounting the unit high in the room will contribute to a consistently humid environment Door and Door Seal An exterio...

Page 10: ...is between 50 70 General Active Humidity Option Recommendations Water source needs to have at least 40 psi Water tubbing size 1 4 O D Water source should be tested for content and characteristics In...

Page 11: ...ess than 3 feet from the floor Note The Humidifier is designed to be mounted with Drywall Anchors 1 Mark the location in which the two screws will be installed Make sure the screws are installed level...

Page 12: ...sure the humidistat electrical is unplugged before installing the unit 2 Position the back half of the humidistat cabinet on the wall or junction box and ensure it is level and covers the junction box...

Page 13: ...n on the top and then pushing inward toward the wall Correct Humidistat Settings 1 Rotate the dial to the desired humidity level 2 Set the bottom selector switch to the Humid setting 3 Set the top sel...

Page 14: ...Copper Pex or equivalent tubing from the water source and connect to the water inlet fitting on the unit as shown in Figure 11 Turn on the water and check for leaks Self Piercing Saddle Valve Install...

Page 15: ...rly connected and used to prevent leakage and other problems associated with excess water It is mandatory to install the drain line whether it leads through the wall and out of the controlled space Fa...

Page 16: ...ibration 2 Check the drain line to see if it is above the waterline if draining into a vessel Quarterly 2 Clean the Humidifier Fan compressed air Annually 1 Inspect for corrosion 2 Check wiring connec...

Page 17: ...talling technician to troubleshoot Compressor keeps cycling on overload Make sure all fans are working and there are no airflow obstruction Poor seal around door or other areas requiring a seal around...

Page 18: ...e following The model and serial number of your CellarCool systems Location of unit and installation details such as ventilation ducting construction of your wine cellar and room size Photos of the ce...

Page 19: ...ssibility of maximum reimbursement of 350 00 in labor for REPAIRING Product on site and supplying all parts at no charge Invoice for service must be forwarded to CellarCool for assessment and processi...

Page 20: ...o not allow the exclusion or limitation of incidental or consequential damages or allow limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to you Th...

Page 21: ...tes However the Purchaser and the End User may be liable to the taxing authority in their state for sales tax and or use tax on the Product The Purchaser and the End User should each check with their...

Page 22: ...al Assistance A Questions If you have any questions regarding these Terms and Conditions or wish to obtain additional information contact us via phone at 1 800 343 9463 or please send a letter via U S...

Page 23: ...arcool com Page 21 Model_______________________________________ Serial Number___________________________ Installed by___________________________________________ Date___________________________ C ACH 5...

Page 24: ...ACH 033114 CellarCool 1738 E Alpine Ave Stockton CA 95205 1 855 235 5271 www cellarcool com...

Reviews: