Performance Specifications
Resolution: 5 µm to approximately 1.22 nm
Maximum travel before position counter rollover, with fringe count bits set to 21: 41.94304
meters
Maximum speed: 10 m/s
Maximum cable length: 10 m
7.6
Index Speed Considerations
MII6000
Maximum Speed for MII6000 Index after Power-up (MII6800, MII6700 and MII6500 Models):
Each time an MII6800, MII6700, or MII6500 encoder is powered up, the first pass over the index
mark must occur at a speed
≤
1 m/s. Once the index is initially detected, the index will function at
all speeds (up to 10 m/s) until the next power cycle.