Sensor Alignment and Calibration
IM-1004 | REV181127
Page 16
©2018 Celera Motion
Mercury II 6000 Series Encoders
Sensor Installation Manual and Reference Guide
Step Action
2. Turn on Align Mode by clicking on the
Align Mode
Turn On
button.
Results:
The
Turn On
button will change to
Turn Off
.
Align Mode Status
will change to
On
(AGC Inactive)
. On the Alignment Tool, both Left and Right Limit LEDs will begin blinking.
3. Adjust the sensor position until the maximum signal strength is achieved. See the Signal Level
Indicator at the top of the SmartPrecision screen.
4. Tighten the sensor mounting screws. Check for index indication (using the status display at the
top right of the screen).
Results:
The Index indication is “not at index” when the sensor is not located at the Index
marker, and “index crossed” when the sensor has passed over the Index marker.
5. Turn off Align Mode by clicking on the
Align Mode
Turn Off
button.
Result:
The
Turn Off
button will change to
Turn On
.
Align Mode Status
will change to
Off
(AGC Active)
. On the Alignment Tool, both Left and Right Limit LEDs will stop blinking.
Signal Level Indicator
Align Mode Turn On/Off Button
Index Indication
Align Mode Turn On/Off Button
Limits Indication