Installation and Operation Manual
IMS 100
© CEDES/April 2014
www.cedes.com
7
3
3..2
2..3
3..
IIn
nsstta
alllla
attiio
on
n o
off ffllu
ussh
h m
mo
ou
un
ntte
ed
d sse
en
nsso
orr
Step Action
Illustration / note (all dimensions in mm)
1
Cut a square shape of 29 x 111 mm out
of the elevator cab transom (1).
Keep the distance to the edge (2) of the
elevator cab transom, hall side, as short
as possible.
→
The
MINIMUM
distance is 17 mm
→
The
MAXIMUM
distance is 250 mm
Drill two 4.7 mm (3/16 inch) diameter
holes for the mounting bracket (4) into
the elevator cab transom (1) with 120 mm
distance on the centerline (CL) of the
shape.
Keep the minimum distance of 7 mm
from the corner of the doorway.
2
Snap the sensor (3) into the mounting
bracket (5).
Align the sensor to the lobby.
Important note:
Observe for side opening doors
.
The sensor must be mounted with the cable outlet facing the door
jamb.
3
Route cable up through the hole in the
elevator cab transom. Slide the sensor
(3) with the mounting bracket (4) into the
hole and fix it with the two mounting clips
(5).
For removal of the clips please refer to
section 4.3
1
2
CL
Hall Side
4
3
5
3
4
Angle: 0 ... 30°
Angle: 0 ... 35°