IMS 100
Installation and Operation Manual
12
www.cedes.com
© CEDES/April 2014
5
5..
TTe
ecch
hn
niicca
all d
da
atta
a
Optical
Detection height
0.6 ... 2.5 m
Detection area at 2 m
200 mm x 900 mm
Min. object detection at 2.5 m
50 mm
Wave length IR
850 nm
Mechanical
Dimensions (w x h x d)
102 x 27 x 23 mm
Housing material
Aluminum, Polycarbonate (PC)
Enclosure rating
IP54
Temperature range
-20 °C … +45 °C
Mechanical adjustment range
30° or 35° (model dependent)
Electrical
Power supply U
SP
24 VDC ±10%
Max. current consumption at 24 VDC
200 mA
Output
PNP
Max. output load
50 mA, 100 nF
Output logic
LOW = object, HIGH = no object
Response time
350 ms
Indication LED (red): LED on
LED off
Object detected
No object detected
Max. optical illumination LED power
0.5 W
Max. recalibration time
1.5 s
Connection cable
and electrical
connection
Length sensor cable
0.5 m
Length connection cable
2.8 m
Diameter
Ø 3.5 mm
Material
PVC, black
Connection
M8, 4-pin
Wires
AWG26
brown
U
SP
blue
GND (0 V)
black
Output (PNP)
white
Time-out selector (18 s or infinity)
General
Eye Safety
EN 62471: 2008
EMC emission
EN 50081-1:1992, EN 12015:2004
EMC immunity
EN 50081-2:1994, EN 12016:2004
Vibration
IEC 60068-2-6:2007
Shock
IEC 60068-2-27:2008
Cable durability
IEC 60227-2:2003
Certificates
CE, CSA
RoHS
2011/65/EU