orrss
Red LED Indication
l
=
LED on
¡
=
LED off
¥
=
LED flashing
Figure 3: Position of LED (1) and sensitive receiver part (2)
¡
-
No power connected or
-
No object detected or
-
Sleeping mode (Reduced scan frequency)
l
Object detected in IMS 100 protection area
¥
Slow flashing:
-
Door mode
à
door has been recognized
-
Sensor keeps flashing as long door is closed
Fast flashing:
-
Sensor in timeout (see Section 3.3.1)
-
Sensor flashing until door recognition (door
mode)
4
4..2
2..
R
Ra
an
nd
do
om
m d
do
oo
orr o
op
pe
en
niin
ng
gss
In case the elevator door is made of glass or a shiny material (e.g. mirror), the door may not be detected by the
sensor during closure. For these applications, place a piece of reflective tape on the inner side of the elevator cab
door that passes in front of the sensor as the door closes (see figure 4 and 5).
Y
x
Inner door
of the cabin
Door frame
Reflective tape
IMS 100 sensor
Figure 4: Reflective tape for side
opening door
Figure 5: Reflective tape for center opening
door
To ensure the reflective tape is positioned within the
sensor’s field of view , the Y distance measurement is
used.
For 30° mounting brackets, use the following formula:
Distance Y = 1.7 * horizontal distance x
For 35° mounting brackets, use the following formula:
Distance Y = 1.4 * horizontal distance x