43
2.3.2
Automatic gas console APGC
This is split into two units: one upper unit, supplied with air
gas, argon Ar, nitrogen N2 and oxygen O2, and one lower
unit supplied by gas H35 (mixture at 35% hydrogen H2 and
65% argon Ar) and F5 (mixture at 5% hydrogen H2 and 95%
nitrogen N2).
TECHNICAL DATA
GASES
USED
TITLE
MAX INLET
PRESSURE
FLOW
RATE
Air
Clean, dry and oil
free as per ISO
8573-1: 2010
standard. Class
1.4.2 (particulate-
water-oil)
*
0.8 MPa (8 bar)
220 l/min
Argon
99.997%
0.8 MPa (8 bar)
70 l/min
Nitrogen
99.997%
0.8 MPa (8 bar)
150 l/min
Oxygen
99.95%
0.8 MPa (8 bar)
90 l/min
H35
Mixture:
35% hydrogen,
65% argon
0.8 MPa (8 bar)
130 l/min
F5
Mixture:
5% hydrogen,
95% azoto
0.8 MPa (8 bar)
30 l/min
*
for the Class 1.4.2, the ISO 8573-1 2010 standard requires:
• Particulate:
≤
20,000 solid particles per m3 of air with size
between 0.1 and 0.5 µm;
≤
400 solid particles per m3 of air with size
between 0.5 and 1.0 µm;
≤
10 solid particles per m3 of air with size betwe-
en 1.0 and 5.0 µm.
• Water:
the air pressure dew point must be below or
same as 3°C.
• Oil:
the total oil concentration must be below or the
same as 0.1 mg per m3 of air.
Duty cycle
100%
Protection rating for the housing
IP 23
Net weight
20 kg
352
289
198
M 6
354
315
Fig. 4
Summary of Contents for Plasma PROF 166 HQC
Page 125: ...125 Fig 20 a T I B A F H G C S E D P Q N O M L R D B A F C G S P Q O N M L R I H E Fig 20 b...
Page 240: ...240 Art 948...
Page 241: ...241 Art 948...
Page 242: ...242 Art 949...
Page 243: ...243 Art 949...
Page 244: ...244 Art 470...
Page 245: ...245 Art 466...
Page 246: ...246 Art 462 Art 469...
Page 250: ...250 Art 949...
Page 252: ...252 Art 470...
Page 254: ...254 Art 466...
Page 258: ...258 Art 462...