Important

 information

 for

 equipment

 safety

Important information for equipment safety 

Important information for equipment safety 

 symbols indicate cautions (also including danger and warning).  

Specific examples are shown in diagrams.  

(A diagram on the left indicates fire warning).

 symbols indicate prohibition.

Specific examples are shown in diagrams.  

(A diagram on the left indicates prohibition to disassemble) 

 symbols indicate instruction for specific actions.

Specific examples are shown in diagrams.  

(A diagram on the left indicates unplugging a power cord)

Examples of safety alert marks

- Read before Use -

- Read before Use -

Incorrect usage of the product may result in fire, electric shock, or other 

serious damages.  Please ensure to follow the conditions below.

3

Warning

Do not disassemble or modify products. 

This may result in fire or electric shock.

Please unplug the power cord when connecting or disconnecting the 

product and peripherals.  Otherwise it may cause fire and/or electric 

shock.
Do not touch the power cords or connect peripheral devices during 

lightning. 

This may result in electric shock.
If abnormal condition occurs such as fuming, product high temperature, 

smell, noise, or so on, stop using the product immediately, and turn the 

power off.

Warning

Indicates incorrect usage may result in serious injury or death.

Caution

Indicates incorrect usage may result in injury or equipment 

damage.

Indication symbols

Caution

Do not place products under the direct sunlight or in high humidity 

environment.

This may result in fire due to internal temperature rise. 

Always ground power cord. 

Otherwise it may result in electric shock.

Be sure to use lights connected to the product within its rating.

Using lights excessing the rating may result in a malfunction of the 

product.
Do not connect lights other than CCS lights to this product.  Doing so 

may result in a malfunction.  Connecting any lights other than CCS lights 

to the product will void the warranty.
Do not connect this product to any products other than In-Sight5000 

series vision sensor.

Doing so may result in a malfunction.

Do not use cables of your own make, such as branch cables.

Doing so may result in a malfunction.

Before moving products, disconnect cables. 

Damaging the cables may result in fire or electric shock.

Do not disconnect power cord or disassemble product while operating.  

Doing so may result in electric shock.

Do not drop or subject products to impact.

Doing so may cause the products to malfunction.

Do not open the product or disassemble connectors. 

By doing so, water and dust proof effect will be lost. 

Do not wipe products with volatiles such as paint thinner or benzene to 

avoid product surface discoloration or deterioration.

Do not short-circuit positive and negative output terminals.

Doing so may cause product failure.

Important information for equipment safety

4

2

Important

 information

 for

 equipment

 safety

Please read "Symbol Examples" carefully for safe usage of products.

FIRE HAZARD

NO DISASSEMBLY 

ALLOWED

UNPLUG

NO DISASSEMBLY 

ALLOWED

FIRE HAZARD

SHOCK HAZARD

UNPLUG

FIRE HAZARD

SHOCK HAZARD

PROHIBITED

INSTRUCTED

PROHIBITED

PROHIBITED

INSTRUCTED

PROHIBITED

PROHIBITED

PROHIBITED

PROHIBITED

PROHIBITED

Summary of Contents for DIL-5000-WV

Page 1: ...rmation Copyright c 2007 CCS Inc All Rights Reserved Description in this user manual is based on the information as of June 2007 KZ01115 T001 001 Thank you for purchasing this CCS s Interface unit for In Sight5000 series In order to properly use this product please read this User Manual before using and keep it for your future references User Manual Model DIL 5000 WV Interface unit for Cognex In S...

Page 2: ...いただき その機能を十分活かしていただくために ご使用の前に必ず本説明書をお読み ください また 常にご覧いただけるよう 大切に保管してください 取扱説明書 型式 DIL 5000 WV In Sight5000シリーズ用 インターフェースユニット Do not use the product by any means in the following situations Conditions or an environment not described in this user manual For nuclear power control railways aircraft any other vehicles combustion equipment medical applications amusement devices or safety devices Situati...

Page 3: ...y environment This may result in fire due to internal temperature rise Always ground power cord Otherwise it may result in electric shock Be sure to use lights connected to the product within its rating Using lights excessing the rating may result in a malfunction of the product Do not connect lights other than CCS lights to this product Doing so may result in a malfunction Connecting any lights o...

Page 4: ... 3 Pin No 12V output type L1 Light 1 24V output type L2 Light 2 1 12V 24V 2 OUT1 NC 3 OUT2 Notes 1 Connect nothing to NC 2 Do not cause a short circuit between output and 3 A total of two channels 28W max Operation panel Interface unit Operation panel Digital window Operation button Channel indication lamp External control indication lamp Nameplate Output connector socket side for the In Sight5000...

Page 5: ...lease refer to information in Chapter 5 Connecting wires To make use of holes for mounting in this interface unit Use M5 screws Need to make Ø6 0 7 0 holes through the fixed place To fix to the fixed place with screws Use M4 screws Need to make M4 holes for mounting in the fixed place M4 fixing screw provided 4 pieces Interface unit In Sight5000 series Break out cable B r e a k o u t c a b l e Eth...

Page 6: ...erioration Operation procedure Procedure for operation using the operation panel This procedure is used to make setting of light control rate through operating the buttons on the operation panel of this interface unit Initial state No display on the window Channel selection Pressing any of the three buttons will display 128 on the window Press the or button to select L1 or L2 Before using In Sight...

Page 7: ...urned OFF In this case turn OFF the power supply and then rectify the error To reset the error turn ON the power supply again Error display The window displays the overcurrent error of L1 If this error is detected the light will be turned OFF forcedly In this case turn OFF the power supply and then rectify the error To reset the error turn ON the power supply again The window displays the voltage ...

Page 8: ...ternal control equipment such as PLC Port No 1 Using the high speed output HSOUT1 from a camera the In Sight5000 series as the trigger Note When the Port No 1 is selected the HSOUT1 cannot be used in equipment other than this interface unit Default value Port No 0 Delay time Setting a delay time prior to LED light pulse Setting in the range of 0 to 1 008μs However setting need to be total of 64 st...

Page 9: ... light The light pulse width can be set in the range of 16 to 100 000μs However Setting need to be a total of 6 250 steps in 16 μs units If the set time cannot be divided by 16μs please round it up Example To set to 500μs 500 16 31 25 round up to 32 32X16 512 Thus 512μs is output Default value 100 000 Used to call from this interface unit scenes registered in the 3 Light control and light pulse wi...

Page 10: ...ting in the Sensor menu 2 Select an external control equipment to be recognized by Input Module in the Discrete Input Setting menu 3 After the completion of selection click the OK button To use the extension I O module 1450 or 1460 from Cognex Select Extension I O Module To use any external control equipment other than that aforementioned Select Standard 3 Make serial port setting 1 Select Serial ...

Page 11: ...please make this setting according to operating environments To use the extension I O module 1450 or 1460 from Cognex Check to be sure that Extension I O Module is selected in the Output Module menu list Select Acquisition Start in the Type menu list of the trigger HSOUT1 High speed output HSOUT1 from the In Sight5000 is used as the trigger 1 When the Trigger Port No 0 is used 2 1 To use other ext...

Page 12: ... to transmit every scene data to the DIL interface unit and save it in the internal memory 4 Call the Scene button Used to call scene data saved in the internal memory of the DIL interface unit For detail of strobe setting please refer to information on page 14 For detail of settings of light control and light pulse width please refer to information on page 15 Call the Scene 2 2k 4 7k TRG TRG 4 7k...

Page 13: ...e buttons is pressed the display light will be on Other display 6 Operating instructions 24 Operating instructions 23 6 Operating instructions The set values of light control data Light1 Light2 and pulse duration can be registered by scene Furthermore a maximum of 8 scene data can be registered The scene data registered are saved in the internal memory of the DIL interface unit When an equipment c...

Page 14: ...shootings Symptom What to inspect and repair In case of operation panel In case of external control serial communications Light is dark Is the light control setting correct Check the setting method and then resetting of the light control data Reference page p 11 Reference page p 15 There is a possibility of product failure Please contact CCS Inc please refer to the back cover Is the shutter timing...

Page 15: ...aximum electric current output Error display on the digital window After the error is rectified reset it by turning ON the power supply again Overpower protection Activated with more than 28W combining channel 1 and 2 Input Protection Error voltage detection 24V DC 10 max 5 min Connector Input M12 connector SACC E12MS 8CON M16 0 5 mfd by Phoenix Contact Output In Sight side M12 connector eight pol...

Page 16: ...er manual and other written cautions during the indicated warranty period of two years CCS Inc will repair or replace the product free of charge if its radiant quantity should drop to 50 or less of its initial radiant quantity under normal use in accordance with the User manual and other written cautions during the indicated warranty period of one year CCS Inc will charge a repair fee under the fo...

Reviews: