Operating instructions
18
6
Operating instructions
Operating instructions
17
6
Operating instructions
Note:
Using an extension I/O module
enables flexible setting of the
protocol. To carr y out direct
serial communications with this
interface unit, make setting of
protocol as shown on the window
on the left.
Baud Rate
Data Bit
Stop Bit
Parity
Handshake
115200
8
1
None
None
Protocol
2. Input setting with an external control equipment
(1) Select “Discrete I/O Setting”, then “Input Setting” in the “Sensor” menu.
(2) Select an external control equipment to be recognized by “Input Module” in the
“Discrete Input Setting” menu.
(3) After the completion of selection, click the “OK” button.
To use the extension I/O module 1450 or 1460 from Cognex;
Select “Extension I/O Module”.
To use any external control equipment other than that aforementioned;
Select “Standard”.
3. Make serial port setting.
(1) Select “Serial Port Setting” in the “Sensor” menu.
(2) Setting of the Protocol on the “Serial Port Setting” window.
1) Select “Text” in the “Mode menu” list.
2) Enter “10” In the Input Terminal Symbol box “LF”.
3) Enter “-1” In the Output Terminal Symbol box “CRLF”.
4) After the completion of setting, click the “OK” button.