RoHS Directive

RoHS Directive

The RoHS Directive is short for the "restriction of use of certain hazardous substances in electrical 

and electronic equipment."  As a directive, it restricts the use of specific hazardous substances for 

new electrical and electronic equipment marketed in the EU on or after July 1, 2006, and restricts 

the use of six substances, which are (1) lead, (2) mercury, (3) cadmium, (4) hexavalent chromium, (5) 

polybrominated biphenyl (PBB), and (6) polybrominated diphenyl ether (PBDE).

EU RoHS Directive

China RoHS Directive is formally known as "Management Methods for Controlling Pollution by 

Electronic Information Products", which was implemented on March 1, 2007 in China.  Same as 

EU RoHS Directive, this regulation restricts the usage of six substances such as lead, mercury, 

cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated diphenyl 

ether (PBDE).  This regulation requires electronic information products which are manufactured or 

imported, and sold in China, to clearly disclose contents of the 6 restricted substances listed below.

China RoHS Directive

*

Standards for "RoHS Directive-Compliant Products"

Lead

Mercury

Cadmium

Hexavalent chromium

PBB

PBDE

1000ppm Min

1000ppm Min

100ppm Min

1000ppm Min

1000ppm Min

1000ppm Min

环保使用期限

产品

有毒有害物质或元素

铅 (Pb)

汞 (Hg)

镉 (Cd)

六价铬 (Cr(VI)) 多溴联苯(PBB) 多溴二苯醚(PBDE)

LED 照明专用电源

×

×

○:表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ/T11363-2006 标准规定的限量要求以下。

×:表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ/T11363-2006 标准规定的限量要求。

(注)铅和镉中的“×”

,因欧洲 RoHS 没限定,故用“○”表示。

产品中有毒有害物质或元素的名称及含量

环保使用期限

此标志的数字是根据中华人民共和国电子信息产品污染控制管理办法以及有关标准等,表示该产品的环保使用期限的年数。

遵守产品的安全和使用上的注意,在产品使用后采取适当的方法根据各地法律,规定,回收再利用或进行废弃处理。

Warranty information

Warranty information

9

RoHS

 Directive

9

9

29

30

(Items that are exempted in the RoHS Directive are excluded from these standards.)

Warranty period: 

Two years (one year for radiant quantity), starting from CCS Inc. shipping date.

CCS Inc. will repair or replace the product free of charge if it should fail to function 

or if the radiant quantity of the product should drop to 50% or less of its initial radiant 

quantity within the specified warranty period. 

If either of these conditions occurs, please take the product to your CCS sales 

representative.

CCS Inc. will repair or replace the product free of charge if it should fail to function

under normal use in accordance with the User manual and other written cautions 

during the indicated warranty period of two years
CCS Inc. will repair or replace the product free of charge if its radiant quantity

should drop to 50% or less of its initial radiant quantity under normal use in 

accordance with the User manual and other written cautions during the indicated 

warranty period of one year.
CCS Inc. will charge a repair fee under the following conditions :

Warranty Terms

1

2

3

1) If the product has been subjected to misuse, unauthorized repairs, or modification from its 

original design.

2) If the product has been damaged from impacts due to inappropriate handling
3) If damage to the product results from external causes including accidents, fire, pollution,

riots, communication failures, earthquakes, thunderstorms, wind and flood damage, or any other 

act of providence, or from any extraordinary conditions such as electrical surges, water leakage, 

condensation, or the use of chemicals

4) If the damage results from connection to any power supply or to any equipment which CCS Inc.

does not  manufacture or does not specify for use

This warranty information provides the scope of CCS's product warranty within the 

specified period, and does not indicate or imply any further guarantee beyond the 

warranty terms.

Contact CCS for inquiries or information on repairs to the product after the expiration 

of the warranty.

Usage Deadline 

for Environmental 

Protection

Product name

Toxic or Hazardous Substances and Elements

Lead

(Pb)

Mercury

(Hg)

Cadmium

(Cd)

Hexavalent 

chromium (Cr(VI))

PBB

PBDE

Power supply for 

LED Lights

    : Indicates that this toxic or hazardous substances contained in all the homogeneous materials for this part, 

according to SJ/T11363-2006 is within the limit requirement. 

    : Indicates that this toxic or hazardous substance contained in all the homogeneous materials for this part,

according to SJ/T11363-2006, is over the limit requirement. 

 

*

Lead and cadmium are excluded in EU RoHS.

Name and amount of toxic and hazardous substances or elements, which products contain

Usage deadline for environmental protection 

The number used in this logo is based on “Management Methods for Controlling Pollution by Electronic 

Information Products” and related regulations from People’s Republic of China.  It shows the product usage 

duration in years for environmental protection.  After finishing a product usage, the product need to be re-

used or discard appropriately following local law and regulations, complying with safety and usage caution.

Summary of Contents for DIL-5000-WV

Page 1: ...rmation Copyright c 2007 CCS Inc All Rights Reserved Description in this user manual is based on the information as of June 2007 KZ01115 T001 001 Thank you for purchasing this CCS s Interface unit for In Sight5000 series In order to properly use this product please read this User Manual before using and keep it for your future references User Manual Model DIL 5000 WV Interface unit for Cognex In S...

Page 2: ...いただき その機能を十分活かしていただくために ご使用の前に必ず本説明書をお読み ください また 常にご覧いただけるよう 大切に保管してください 取扱説明書 型式 DIL 5000 WV In Sight5000シリーズ用 インターフェースユニット Do not use the product by any means in the following situations Conditions or an environment not described in this user manual For nuclear power control railways aircraft any other vehicles combustion equipment medical applications amusement devices or safety devices Situati...

Page 3: ...y environment This may result in fire due to internal temperature rise Always ground power cord Otherwise it may result in electric shock Be sure to use lights connected to the product within its rating Using lights excessing the rating may result in a malfunction of the product Do not connect lights other than CCS lights to this product Doing so may result in a malfunction Connecting any lights o...

Page 4: ... 3 Pin No 12V output type L1 Light 1 24V output type L2 Light 2 1 12V 24V 2 OUT1 NC 3 OUT2 Notes 1 Connect nothing to NC 2 Do not cause a short circuit between output and 3 A total of two channels 28W max Operation panel Interface unit Operation panel Digital window Operation button Channel indication lamp External control indication lamp Nameplate Output connector socket side for the In Sight5000...

Page 5: ...lease refer to information in Chapter 5 Connecting wires To make use of holes for mounting in this interface unit Use M5 screws Need to make Ø6 0 7 0 holes through the fixed place To fix to the fixed place with screws Use M4 screws Need to make M4 holes for mounting in the fixed place M4 fixing screw provided 4 pieces Interface unit In Sight5000 series Break out cable B r e a k o u t c a b l e Eth...

Page 6: ...erioration Operation procedure Procedure for operation using the operation panel This procedure is used to make setting of light control rate through operating the buttons on the operation panel of this interface unit Initial state No display on the window Channel selection Pressing any of the three buttons will display 128 on the window Press the or button to select L1 or L2 Before using In Sight...

Page 7: ...urned OFF In this case turn OFF the power supply and then rectify the error To reset the error turn ON the power supply again Error display The window displays the overcurrent error of L1 If this error is detected the light will be turned OFF forcedly In this case turn OFF the power supply and then rectify the error To reset the error turn ON the power supply again The window displays the voltage ...

Page 8: ...ternal control equipment such as PLC Port No 1 Using the high speed output HSOUT1 from a camera the In Sight5000 series as the trigger Note When the Port No 1 is selected the HSOUT1 cannot be used in equipment other than this interface unit Default value Port No 0 Delay time Setting a delay time prior to LED light pulse Setting in the range of 0 to 1 008μs However setting need to be total of 64 st...

Page 9: ... light The light pulse width can be set in the range of 16 to 100 000μs However Setting need to be a total of 6 250 steps in 16 μs units If the set time cannot be divided by 16μs please round it up Example To set to 500μs 500 16 31 25 round up to 32 32X16 512 Thus 512μs is output Default value 100 000 Used to call from this interface unit scenes registered in the 3 Light control and light pulse wi...

Page 10: ...ting in the Sensor menu 2 Select an external control equipment to be recognized by Input Module in the Discrete Input Setting menu 3 After the completion of selection click the OK button To use the extension I O module 1450 or 1460 from Cognex Select Extension I O Module To use any external control equipment other than that aforementioned Select Standard 3 Make serial port setting 1 Select Serial ...

Page 11: ...please make this setting according to operating environments To use the extension I O module 1450 or 1460 from Cognex Check to be sure that Extension I O Module is selected in the Output Module menu list Select Acquisition Start in the Type menu list of the trigger HSOUT1 High speed output HSOUT1 from the In Sight5000 is used as the trigger 1 When the Trigger Port No 0 is used 2 1 To use other ext...

Page 12: ... to transmit every scene data to the DIL interface unit and save it in the internal memory 4 Call the Scene button Used to call scene data saved in the internal memory of the DIL interface unit For detail of strobe setting please refer to information on page 14 For detail of settings of light control and light pulse width please refer to information on page 15 Call the Scene 2 2k 4 7k TRG TRG 4 7k...

Page 13: ...e buttons is pressed the display light will be on Other display 6 Operating instructions 24 Operating instructions 23 6 Operating instructions The set values of light control data Light1 Light2 and pulse duration can be registered by scene Furthermore a maximum of 8 scene data can be registered The scene data registered are saved in the internal memory of the DIL interface unit When an equipment c...

Page 14: ...shootings Symptom What to inspect and repair In case of operation panel In case of external control serial communications Light is dark Is the light control setting correct Check the setting method and then resetting of the light control data Reference page p 11 Reference page p 15 There is a possibility of product failure Please contact CCS Inc please refer to the back cover Is the shutter timing...

Page 15: ...aximum electric current output Error display on the digital window After the error is rectified reset it by turning ON the power supply again Overpower protection Activated with more than 28W combining channel 1 and 2 Input Protection Error voltage detection 24V DC 10 max 5 min Connector Input M12 connector SACC E12MS 8CON M16 0 5 mfd by Phoenix Contact Output In Sight side M12 connector eight pol...

Page 16: ...er manual and other written cautions during the indicated warranty period of two years CCS Inc will repair or replace the product free of charge if its radiant quantity should drop to 50 or less of its initial radiant quantity under normal use in accordance with the User manual and other written cautions during the indicated warranty period of one year CCS Inc will charge a repair fee under the fo...

Reviews: