background image

6

NOTE:

If no display appears on the LCD after you plug the adaptor, press 

[ RESET ]

 key by using a pointed object .

SET LCD DISPLAY VIEWING ANGLE

Press 

[   ]

 or 

[   ]

 key in normal mode to adjust LCD viewing angle to fit table stand or wall 

mount situation .

BUILT-IN MEMORY

The console has built-in FLASH memory that holds the vital settings . These include:

 

-

Time Zone, DST status, Time SYNC status, WI-FI and Weather server setting, Latitude / Longitude, 

Hemisphere setting, Calibration values, and Sensor ID of paired sensor(s)

RESET AND FACTORY HARD RESET

 To reset the console and start again, press the 

[ RESET ]

 key once or remove the backup battery and 

then unplug the adapter . To resume factory settings and remove all data, press and hold the 

[ RESET ]

 key 

for 6 seconds . 

RESYNCHRONIZE SENSORS

Press the 

[ SENSOR / WI-FI ]

 key once for the console to enter sensor Synchronization mode, and the 

console will re-register all the sensors that have already been registered to the it before . i .e . the console will 

not lose the connection of the sensors that you’d paired up before .

CHANGING BATTERIES AND MANUAL PAIRING OF SENSOR

Whenever you changed the batteries of the wireless indoor or 7-in-1 weather sensor, re-

synchronization must be done manually .

1 .  Change all the batteries to new ones in the sensor .

2 .  Press 

[ SENSOR / WI-FI ]

 key on the console to enter sensor synchronization mode .

3 .  Press 

[ RESET ]

 key on the wireless indoor or 7-in-1 weather sensor .

SYNCHRONIZING ADDITIONAL WIRELESS SENSOR(S) (OPTIONAL)

The console can support up to 7 additional wireless sensors .

1 .  Press the 

[ SENSOR / WI-FI ]

 key once on the console to enter synchronization mode .

2 .  Press the 

[ RESET ]

 key on the new sensor, and wait for a few minutes for the new sensor 

to paired to the console .

NOTE:

 -Channel number of the indoor sensor must not be duplicated among the sensors . Please refer to 

INSTALL WIRELESS INDOOR SENSOR

” for details

 -

This console can support different type of additional wireless sensor, e.g. soil moisture and pool sensor. If 

you would like to pair up additional sensors, please check with your retailer for more detail .

POINTING THE WIRELESS 7-IN-1 SENSOR TO SOUTH 

The wireless 7-IN-1 sensor is calibrated to point to North for the maximum accuracy . However, for the 

user's convenience (e .g . users in the Southern hemisphere), it is possible to use the sensor with the wind 

vane pointing to South .

1 .  Install the 7-IN-1 wireless sensor with its wind meter end pointing to South . (Please refer to 

INSTALLATION OF THE WIRELESS SENSOR

 section for mounting details)

2 .  Select "S' in hemisphere section of the setup UI setup page . (Please refer to 

SETUP THE 

WEATHER SERVER CONNECTION

 section for setup details)

3 .  Press 

Apply

 icon to confirm and exit.

NOTE: 

Changing the hemisphere setting will automatically switch the direction of the moon phase on the display .

Summary of Contents for C6078A

Page 1: ...WI FI weather station with 7 In 1 professional sensor Model C6078A User Manual...

Page 2: ...13 FIRMWARE UPDATE 13 OTHER SETTING FUNCTIONS OF THE CONSOLE 14 MANUAL CLOCK SETTING 14 SETTING ALARM TIME 14 ACTIVATING ALARM AND TEMPERATURE PRE ALARM FUNCTION 15 MOON PHASE 15 TEMPERATURE HUMIDITY...

Page 3: ...ct is not a toy Keep out of the reach of children The console is intended to be used only indoors This product is intended for use only with the adaptor provided Manufacturer HUAXU Electronics Factory...

Page 4: ...y 4 HISTORY key 5 MAX MIN key 6 SUN key 7 WIND key 8 BARO key 9 RAIN key 10 LCD display 11 CLOCK SET key 12 ALARM key 13 Wall mounting hole 14 ALERT key 15 NDX key 16 key 17 Power jack 18 SENSOR WI FI...

Page 5: ...IN 1 SENSOR Your wireless 7 IN 1 sensor measures wind speed wind direction rainfall UV index light intensity temperature and humidity for you It s fully assembled and calibrated for your easy install...

Page 6: ...tand then insert the screw in other side and then tighten it by the screw driver Install the wireless 7 IN 1 sensor in an open location with no obstructions above and around the sensor for accurate ra...

Page 7: ...CONSOLE Your console can pairing up with the wireless 7 IN 1 wireless weather sensor and up to 7 optional wireless sensors Not included INSTALL THE BACKUP BATTERY 1 Detach the table stand 2 Remove the...

Page 8: ...on the console to enter sensor synchronization mode 3 Press RESET key on the wireless indoor or 7 in 1 weather sensor SYNCHRONIZING ADDITIONAL WIRELESS SENSOR S OPTIONAL The console can support up to...

Page 9: ...email address to register your account 2 After you have created your account and completed the Email validation please go back to the WUndergound web page to login Then click My Pro le button on the...

Page 10: ...UD ACCOUNT 1 In https weathercloud net enter your information in Join us today section then follow the instructions to create your account NOTE Use the valid email address to register your account 2 S...

Page 11: ...reate new device page for the Model selection box select the W100 Series under CCL section For the Link type selection box select the SETTINGS Once you have completed click Create 4 Jot down your ID a...

Page 12: ...veral second to connect PWS XXXXXX PWS XXXXXX PC Windows 10 WI FI network interface Android WI FI network interface 4 Once connected enter the following IP address into your Internet browser s address...

Page 13: ...I display language Press to complete the setting Select router SSID for connection Enter new Station ID and Station key that assigned by Wundergriund Enter new Station ID and Station key that assigned...

Page 14: ...1 5 Current offset 3 Current offset 3 Default 0 Current offset 10 Default 0 Current offset 0 2 Current offset 5 Current offset 1 Pressure Range 20 0 20 0o C 36 0 36 0o F Default 0 0 UV gain Range 0 01...

Page 15: ...You can also check Weather Underground web site to learn more about their mobile App for Android and iOS VIEWING YOUR WEATHER DATA IN WEATHERCLOUD 1 To view your weather station live data in a web br...

Page 16: ...ion again Firmware update process have potential risk which cannot guarantee 100 success If the update fail please redo the above step to update again OTHER SETTING FUNCTIONS OF THE CONSOLE MANUAL CLO...

Page 17: ...me alarm sound will start Where it can be stopped by following operation Auto stop after 2 minutes alarming if without any operation and the alarm will activate again in the next day By pressing ALARM...

Page 18: ...ill display Er for the corresponding channel 3 If the signal does not recover within 48 hours the Er display will become permanent You need to replace the batteries and then press SENSOR WI FI key to...

Page 19: ...ight air 1 1 5km h Smoke drift indicates wind direction Leaves and wind vanes are stationary 1 3 mph 1 3 knots 0 3 1 5 m s 2 Light breeze 6 11 km h Wind felt on exposed skin Leaves rustle Wind vanes b...

Page 20: ...n between 18 1 C to 25 9 C where both wind and humidity are less significant in affecting the temperature the device will show the actual measured temperature as Feels Like Temperature DEW POINT The d...

Page 21: ...e variation in atmospheric pressure greatly affected by weather it is possible to forecast the weather by measuring the changes in pressure TO VIEW THE BAROMETRIC PRESSURE IN DIFFERENT UNIT 1 In norma...

Page 22: ...ommended protection indicator N A Moderate or high UV level Suggest to wear sunglasses broad brim hat and long sleeved clothing Very high or Extreme UV level Suggest to wear sunglasses broad brim hat...

Page 23: ...ype Setting Range Display Section Default Out Temperature High Alert 40 C 80 C Out temperature humidity 40 C Out Temperature Low Alert 0 C Out Humidity High Alert 1 99 80 Out Humidity Low Alert 40 In...

Page 24: ...gs will still keep flash until the weather reading is out of the alert range The weather alert will sound again when the weather readings falls into the alert range again BACK LIGHT The main unit back...

Page 25: ...connection 1 Make sure the sensor is within the transmission range 2 If it still not work reset the sensor and resynchronize with console Indoor wireless sensor is intermittent or no connection 1 Mak...

Page 26: ...ser for setup UI Web browsers that support HTML 5 such as the latest version of Chrome Safari Edge Firefox or Opera Wireless Sensor side Communication Specification Support sensors 1 Wireless 7 IN 1 w...

Page 27: ...20 RH 6 5 RH 25 C 77 F 21 80 RH 3 5 RH 25 C 77 F 81 99 RH 6 5 RH 25 C 77 F Resolution 1 Memory modes Historical data of past 24 hours Max Min Wind Speed Direction Note Data detect by 7 in 1 sensor Win...

Page 28: ...Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may caus...

Page 29: ...27...