Humidity unit

%

Accuracy

1 ~ 20% RH ± 6.5% RH @ 25°C (77°F)

21 ~ 80% RH ± 3.5% RH @ 25°C (77°F)

81 ~ 99% RH ± 6.5% RH @ 25°C (77°F)

Resolution

1%

WI-FI Communication Specification

Standard

802.11 b/g/n

Operating frequency :

2.4GHz

Supported router security 
type

WPA/WPA2, OPEN, WEP (WEP only support Hexadecimal 

password)

APP Specification

Support App

- Tuya smart
- Smart Life

Supported platform of App

Android smart phone
iPhone

WIRELESS THERMO-HYGRO SENSOR

Dimensions (W x H x D)

60 x 113 x 39.5mm (2.4 x 4.4 x 1.6in)

Weight

130g (with batteries)

Main power

2 x AA size 1.5V batteries 

( Lithium batteries recommended)

Weather data

Temperature and Humidity 

RF transmission range

150m

RF frequency (depend on 
country version)

915Mhz (US) / 868Mhz (EU, UK) / 917Mhz (AU)

Transmission interval

60 seconds for temperature and humidity

Operating range

-40 ~ 60°C (-40 ~ 140°F)  Lithium batteries required

Operating humidity range

1 ~ 99% RH

CH (wireless sensor) Temperature

Temperature unit

°C and °F

Accuracy

5.1 ~ 60°C ± 0.4°C (41.2 ~ 140°F ± 0.7°F)

-19.9 ~ 5°C ± 1°C (-3.8 ~ 41°F ± 1.8°F)

-40 ~ -20°C ± 1.5°C (-40 ~ -4°F ± 2.7°F)

Resolution

°C / °F (1 decimal place)

CH (wireless sensor) Humidity

Humidity unit

%

Accuracy

1 ~ 20% RH ± 6.5% RH @ 25°C (77°F)

21 ~ 80% RH ± 3.5% RH @ 25°C (77°F)

81 ~ 99% RH ± 6.5% RH @ 25°C (77°F)

Resolution

1%

Summary of Contents for C3126A

Page 1: ...Smart multi channel weather station with wireless sensor Model C6082A C3126A User Manual Smart phone not included...

Page 2: ...and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that inter...

Page 3: ...TION 14 BACK LIGHT 14 SET LCD DISPLAY CONTRAST 15 MAINTENANCE 15 BATTERY REPLACEMENT 15 TROUBLESHOOT 15 SPECIFICATION 15 CONSOLE 15 WIRELESS THERMO HYGRO SENSOR 16 ABOUT THIS USER S MANUAL This symbol...

Page 4: ...torage or transportation if not it may result in an explosion or the leakage of flammable liquid or gas Disposal of a battery into fire or a hot oven or mechanically crushing or cutting of a battery t...

Page 5: ...ANNEL key 4 MODE ALARM key 5 MAX MIN key 6 HI LO slide switch 7 CAL key 8 TIME SET key 9 Table stand 10 Battery door 11 Wall mounting hole 12 C F key 13 Refresh key 14 RESET key 15 SENSOR WI FI key 16...

Page 6: ...tered to the console within the next few minutes The transmission status LED will begin to flash every 1 minute NOTE If you need to re assign the sensor channel slide the channel slide switch to the n...

Page 7: ...router Stable Connected to router Stable Connected to router and synchronized to local time Flashing Console currently in Access Point AP mode Blinking Sensor synchronization process 4 The wireless s...

Page 8: ...from the console 1 Press the CHANNEL key until the console shows the display of the selected sensor 2 Press and hold REFRESH key for 10 seconds until its readings are reset C is shown SMART LIFE APP...

Page 9: ...n and you can customize its information Step 4 Confirm your device is in AP mode and tap Next Step 3 Make sure you select the 2 4G network and enter your Wi Fi password then tap the Next Step 7 The co...

Page 10: ...d access to graphs alert setting alert history and unit conversion 1 Temperature and humidity reading with max min records for INDOOR 2 Temperature and humidity reading with max min records for wirele...

Page 11: ...e Screen Step 2 Tap the Temperature Alarm or Humidity Alarm Step 3 Tap the INDOOR or CH 1 7 Step 4 Set the High Low trigger values and slide the switch to activate the alert AUTOMATION WITH OTHER DEVI...

Page 12: ...ap one of below tag to set different trigger condition NOTE Any tasks required or performed by third party devices are at user s own choice and risk Please note no guarantee can be assumed regarding t...

Page 13: ...iginal version then redo the update procedure again OTHER SETTING FUNCTIONS OF THE CONSOLE MANUAL CLOCK SETTING This console is designed to obtain the local time by synchronizing with your local time...

Page 14: ...he signal does not recover within 48 hours the Er display will become permanent You need to replace the batteries and then press SENSOR WI FI key to pair up the sensor again VIEW THE OTHER CHANNELS OP...

Page 15: ...k records of different sensor by pressing CHANNEL key TO RESET THE MAX MIN RECORDS Press and hold MAX MIN key for 2 seconds to reset the current on display MAX or MIN records NOTE The LCD will also di...

Page 16: ...emperature or humidity not accurate 1 Do not place your console or sensor close to the heat source 2 If the sensor still not accurate adjust the value in calibration mode SPECIFICATIONS CONSOLE Genera...

Page 17: ...with batteries Main power 2 x AA size 1 5V batteries Lithium batteries recommended Weather data Temperature and Humidity RF transmission range 150m RF frequency depend on country version 915Mhz US 86...

Reviews: