16
SET LCD DISPLAY CONTRAST
In normal mode, press
[ / CAL ]
key to adjust LCD contrast for best viewing on table stand or
wall mounted.
MAINTENANCE
BATTERY REPLACEMENT
When low battery indicator “
” is displayed in CH section of the LCD display, it indicates that
the current channel sensor battery power give wireless sensor shown is low respectively. Please
replace with new batteries.
TROUBLESHOOT
Problems
Solution
Indoor wireless
sensor is intermittent
or no connection
1. Make sure the sensor is within the transmission range
2. Make sure the channel displayed match to the channel selection
on sensor
3.
If it still not work, reset the sensor and resynchronize with console.
No WI-FI connection
1. Check for WI-FI symbol on the display, it should be alway on.
2. Make sure you connect to 2.4G band but not 5G band of your WI-
FI router.
Temperature or
humidity not accurate
1. Do not place your console or sensor close to the heat source
2. If the sensor still not accurate adjust the value in calibration mode.
SPECIFICATIONS
CONSOLE
General Specification
Dimensions (W x H x D)
130 x 112 x 27.5mm (5.1 x 4.4 x 1.1 in)
Weight
220g (with batteries)
Main power
DC 5V, 1A adaptor
Backup battery
CR2032
Operating temperature range
-5˚C ~ 50˚C
Operating Humidity range
10~90% RH
Support sensors
- 1 Wireless Thermo-hygro sensors (included)
- Support Up to 7 Wireless Thermo-hygro sensors (optional)
RF frequency
(Depend on country version)
915Mhz (US version) / 868Mhz (EU or UK version) /
917Mhz (AU version)
Time Related Function Specification
Time display
HH: MM
Hour format
12hr AM / PM or 24 hr
Date display
DD / MM or MM / DD
Time synchronize method
Through the server to get the local time of the console location
Weekday languages
EN / DE / FR / ES / IT / NL / RU
In Temperature
Temperature unit
°C and °F
Accuracy
<0°C or >40°C ± 2°C (<32°F or >104°F ± 3.6°F)
0~40°C ±1°C (32~104°F ± 1.8°F)
Resolution
°C / °F (1 decimal place)