background image

2

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may cause undesired operation.

Warning: Changes or modifications to this unit not expressly approved by the party responsible 

for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, 
uses and can radiate radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.

- Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

- Consult the dealer or an experienced radio/TV technician for help.

“ FCC RF Radiation Exposure Statement

Caution: To maintain compliance with the FCC’s RF exposure guidelines, place the unit at least 

20cm from nearby persons.”

Summary of Contents for C3126A

Page 1: ...Smart multi channel weather station with wireless sensor Model C6082A C3126A User Manual Smart phone not included...

Page 2: ...and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that inter...

Page 3: ...TION 14 BACK LIGHT 14 SET LCD DISPLAY CONTRAST 15 MAINTENANCE 15 BATTERY REPLACEMENT 15 TROUBLESHOOT 15 SPECIFICATION 15 CONSOLE 15 WIRELESS THERMO HYGRO SENSOR 16 ABOUT THIS USER S MANUAL This symbol...

Page 4: ...torage or transportation if not it may result in an explosion or the leakage of flammable liquid or gas Disposal of a battery into fire or a hot oven or mechanically crushing or cutting of a battery t...

Page 5: ...ANNEL key 4 MODE ALARM key 5 MAX MIN key 6 HI LO slide switch 7 CAL key 8 TIME SET key 9 Table stand 10 Battery door 11 Wall mounting hole 12 C F key 13 Refresh key 14 RESET key 15 SENSOR WI FI key 16...

Page 6: ...tered to the console within the next few minutes The transmission status LED will begin to flash every 1 minute NOTE If you need to re assign the sensor channel slide the channel slide switch to the n...

Page 7: ...router Stable Connected to router Stable Connected to router and synchronized to local time Flashing Console currently in Access Point AP mode Blinking Sensor synchronization process 4 The wireless s...

Page 8: ...from the console 1 Press the CHANNEL key until the console shows the display of the selected sensor 2 Press and hold REFRESH key for 10 seconds until its readings are reset C is shown SMART LIFE APP...

Page 9: ...n and you can customize its information Step 4 Confirm your device is in AP mode and tap Next Step 3 Make sure you select the 2 4G network and enter your Wi Fi password then tap the Next Step 7 The co...

Page 10: ...d access to graphs alert setting alert history and unit conversion 1 Temperature and humidity reading with max min records for INDOOR 2 Temperature and humidity reading with max min records for wirele...

Page 11: ...e Screen Step 2 Tap the Temperature Alarm or Humidity Alarm Step 3 Tap the INDOOR or CH 1 7 Step 4 Set the High Low trigger values and slide the switch to activate the alert AUTOMATION WITH OTHER DEVI...

Page 12: ...ap one of below tag to set different trigger condition NOTE Any tasks required or performed by third party devices are at user s own choice and risk Please note no guarantee can be assumed regarding t...

Page 13: ...iginal version then redo the update procedure again OTHER SETTING FUNCTIONS OF THE CONSOLE MANUAL CLOCK SETTING This console is designed to obtain the local time by synchronizing with your local time...

Page 14: ...he signal does not recover within 48 hours the Er display will become permanent You need to replace the batteries and then press SENSOR WI FI key to pair up the sensor again VIEW THE OTHER CHANNELS OP...

Page 15: ...k records of different sensor by pressing CHANNEL key TO RESET THE MAX MIN RECORDS Press and hold MAX MIN key for 2 seconds to reset the current on display MAX or MIN records NOTE The LCD will also di...

Page 16: ...emperature or humidity not accurate 1 Do not place your console or sensor close to the heat source 2 If the sensor still not accurate adjust the value in calibration mode SPECIFICATIONS CONSOLE Genera...

Page 17: ...with batteries Main power 2 x AA size 1 5V batteries Lithium batteries recommended Weather data Temperature and Humidity RF transmission range 150m RF frequency depend on country version 915Mhz US 86...

Reviews: