background image

8

ADDITIONAL WIRELESS SENSOR(S) (OPTIONAL)

The console can support up to 7 wireless sensors.

1.  In the new wireless sensor, slide the Channel switch to a new CH number
2.  Press the 

[ RESET ]

 key on the new sensor.

3.  At the back of the console, press the 

[ SENSOR / WI-FI ]

 key enter sensor synchronization 

mode

4.  Wait for the new sensor(s) to pair up with the console. (about 1 minute)
5.  Once the new sensor(s) are connected to the console successfully, their temperature and 

humidity will be shown accordingly.

 NOTE:

 

- Channel number of the sensor must not be duplicated among the sensors. Please refer to “

INSTALL 

Wireless thermo-hygro SENSOR

” for details

 

-

This console can support different type of additional wireless sensor(s), e.g. soil moisture. If you 

would like to pair up additional sensors, please check with your retailer for more detail.

SENSOR(S) RESYNCHRONIZATION

Press the 

[ SENSOR / WI-FI ]

 key once for the console to enter sensor Synchronization mode 

(channel number blinking), and the console will re-register all the sensors that have already 
been paired to it before.

REMOVE WIRELESS SENSOR

User may manually delete any sensor from the console.
1.  Press the 

[ CHANNEL ]

 key until the console shows the display of the selected sensor.

2.  Press and hold 

[ REFRESH ] 

key for 10 seconds, until its readings are reset " -- , -

°C -- % " 

is shown.

SMART LIFE APP

ACCOUNT REGISTRATION

The console works with Smart Life App for Android and iOS smart phone.

1.  Scan the QR code to go to the Smart Life download page
2.  Download Smart Life from Google Play or Apple App store.
3.  Install the Smart Life App.
4.  Follow the instruction to create your own account using phone 

number or email.

5.  Once the account registration is completed, the Home Screen 

will be shown.

Smart Life for 

Andriod /IPhone

 NOTE: 

 

- There is no Registration code needed if email method is chosen.

 

- The  App may be subject to change without notice.

 

- You may be prompted to allow the App to have access to your location. This will allow the app to give you 

general weather information in your area. The app will still work if you don' t allow access to that.

CONNECT WEATHER STATION TO WIFI NETWORK

1.  Press and hold the 

[ SENSOR / WI-FI ] 

key for 6 seconds to enter AP mode manually, 

indicated by blinking AP and 

 . When the console is power up for the first time, the console 

will automatically enter and stay at AP mode.

2.  Open Smart Life App and follow the in-app instructions to connect weather station to your   

Wi-Fi network.

Summary of Contents for C3126A

Page 1: ...Smart multi channel weather station with wireless sensor Model C6082A C3126A User Manual Smart phone not included...

Page 2: ...and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that inter...

Page 3: ...TION 14 BACK LIGHT 14 SET LCD DISPLAY CONTRAST 15 MAINTENANCE 15 BATTERY REPLACEMENT 15 TROUBLESHOOT 15 SPECIFICATION 15 CONSOLE 15 WIRELESS THERMO HYGRO SENSOR 16 ABOUT THIS USER S MANUAL This symbol...

Page 4: ...torage or transportation if not it may result in an explosion or the leakage of flammable liquid or gas Disposal of a battery into fire or a hot oven or mechanically crushing or cutting of a battery t...

Page 5: ...ANNEL key 4 MODE ALARM key 5 MAX MIN key 6 HI LO slide switch 7 CAL key 8 TIME SET key 9 Table stand 10 Battery door 11 Wall mounting hole 12 C F key 13 Refresh key 14 RESET key 15 SENSOR WI FI key 16...

Page 6: ...tered to the console within the next few minutes The transmission status LED will begin to flash every 1 minute NOTE If you need to re assign the sensor channel slide the channel slide switch to the n...

Page 7: ...router Stable Connected to router Stable Connected to router and synchronized to local time Flashing Console currently in Access Point AP mode Blinking Sensor synchronization process 4 The wireless s...

Page 8: ...from the console 1 Press the CHANNEL key until the console shows the display of the selected sensor 2 Press and hold REFRESH key for 10 seconds until its readings are reset C is shown SMART LIFE APP...

Page 9: ...n and you can customize its information Step 4 Confirm your device is in AP mode and tap Next Step 3 Make sure you select the 2 4G network and enter your Wi Fi password then tap the Next Step 7 The co...

Page 10: ...d access to graphs alert setting alert history and unit conversion 1 Temperature and humidity reading with max min records for INDOOR 2 Temperature and humidity reading with max min records for wirele...

Page 11: ...e Screen Step 2 Tap the Temperature Alarm or Humidity Alarm Step 3 Tap the INDOOR or CH 1 7 Step 4 Set the High Low trigger values and slide the switch to activate the alert AUTOMATION WITH OTHER DEVI...

Page 12: ...ap one of below tag to set different trigger condition NOTE Any tasks required or performed by third party devices are at user s own choice and risk Please note no guarantee can be assumed regarding t...

Page 13: ...iginal version then redo the update procedure again OTHER SETTING FUNCTIONS OF THE CONSOLE MANUAL CLOCK SETTING This console is designed to obtain the local time by synchronizing with your local time...

Page 14: ...he signal does not recover within 48 hours the Er display will become permanent You need to replace the batteries and then press SENSOR WI FI key to pair up the sensor again VIEW THE OTHER CHANNELS OP...

Page 15: ...k records of different sensor by pressing CHANNEL key TO RESET THE MAX MIN RECORDS Press and hold MAX MIN key for 2 seconds to reset the current on display MAX or MIN records NOTE The LCD will also di...

Page 16: ...emperature or humidity not accurate 1 Do not place your console or sensor close to the heat source 2 If the sensor still not accurate adjust the value in calibration mode SPECIFICATIONS CONSOLE Genera...

Page 17: ...with batteries Main power 2 x AA size 1 5V batteries Lithium batteries recommended Weather data Temperature and Humidity RF transmission range 150m RF frequency depend on country version 915Mhz US 86...