Technical information
sheet
MeteoR2
v3.2EN
Screen
Function
• Heat. : Heating
• Boost. : Booster pump
Heating/ Frost
Yes / No
If auxiliary 1 is configured as HEATING mode, this screen is
used to activate it when the control box is in freeze protection
mode.
Level Control
Fill
This screen is used to select the type of level regulation:
• None: No level regulation.
• Top-up : Top-up only; corresponds to KIT-NIV ref
PF10K006/V02.
• Overfl. : Overflow regulation (channel); corresponds to
KIT-NIV4 ref PF10K009.
• Safety: Pump stop + automatic top-up; corresponds to
KIT-FLOT ref SF140008.
AUX 1 controlled
Yes / No
This screen is used to configure whether the "auxiliary 1"
output is coupled to filtering or not. This option can only be
set to "No" if auxiliary 1 is configured as "Auxil." (the Aux-
iliary 1 output is always coupled if configured as treatment,
heating or booster pump).
DST Auto
Yes / No
This screen is used to automatically configure changes to
Daylight Saving Time.
• Yes: Automatic switch to summer time is enabled.
• No: Automatic switch to summer time is disabled.
Aux 2 controlled
Yes / No
This screen is used to configure whether the "auxiliary 2"
output (power socket) is coupled to filtering or not.
• Yes: The auxiliary 2 output will only be activated if filter-
ing is running.
• No: The auxiliary 2 output can be activated independently
of filtering.
Remote control
0011
This screen is used to configure the remote control code.
When interferences hinder the appliance's operation (for ex-
ample if there are severalMeteoR2 in the neighbourhood) it
may be necessary to select different codes for each appliance.
See below.
Display no
1
This screen is used to provide the display address for the fu-
ture extension of the system (remote display, Zen'iT, etc.).
Leave this setting on "1" on the control box!