Technical information
sheet
MeteoR2
v3.2EN
5.4.2. System status (supervisor)
The following additional system status screens are available in supervisor mode;
Screen
Function
METEOR-2
Firmware A/B
vX.Y
Displays the versions of the programmes loaded into your con-
trol box. The display alternates between "Firmware A", which
gives the display card programme version, and "Firmware B",
which gives the base programme version (power module)
MENU
F 0.0A (4.5A)
FILTERING STATUS: In addition to the filtering daily and
hour counters described previously, this screen also displays the
value of the current measured by the appliance with the pump's
calibrated value in brackets (4.5A in the example). There is an
F when only filtering is running, or FB if the booster pump is
running.
5.4.3. MENU CONFIGURATION (supervisor)
The following additional configuration screens are available in supervisor mode;
Screen
Function
Log
Event
This screen is used to access the following data:
• #1 cx --/--/---- : Date of the last event:
– c4: Filter pump current too weak
– c5: Filter pump current too strong
– c6: Low water level
• #2 c1 --/--/---- : Commissioning date (1 hour after first
commissioning).
• #3 c3 --/--/---- : Date freeze protection was last activated
Type of light
Brio RC+
This screen is used to select the type of floodlights installed:
• Mono: Monochrome lighting.
• T. Switch: Used to control most colour changes using mi-
cro power cuts (Toggle Switch).
• Brio RC: Used to control CCEI lighting compatible with
BRIO RC.
• Brio RC+: Used to control CCEI lighting compatible with
BRIO RC+.
AUX 1 function
Auxil.
This screen is used to select the type of auxiliary output:
• Auxil. : Auxiliary
• Ttmt: Treatment / electrolysis
www.c-
cei.fr
40