For maximum flexibility the CaviBlaster
®
power unit should be installed in an area
where it is capable of reaching both its water source and anticipated cleaning
targets within acceptable hose lengths. The CaviBlaster
®
power unit can be
installed in an enclosed* or open environment.
*Enclosed installations will require provisions for adequate engine cooling
air flow and for venting of engine exhaust. See Figure 4.2 below.
Installation location must be a level surface able to safely support the unit weight
listed in Section 1.0
UNIT SPECIFICATIONS
. Orient unit to allow unrestricted
access to the hose connection plate and control panel, located on the front of the
unit. Allow a minimum of three feet behind the unit and access from above to
conduct service and repair work. Take note of frequently serviced areas such as
the engine, belts and fuel tank.
Figure 4.2
– Installation Guidelines
Fuel tank
filling port
Allow access to
control panel &
ignition panel
Allow access to
PTO and to
service belts
Allow access for
general service
Access required far
side for emergency
air shut off
(Chalwyn) valve.