43
F-P
.....
F
requency-
p
ulsing ... (pulsing frequency) ... OFF / 0.20 Hz to 990 Hz
Factory setting: OFF
The pre-set pulsing frequency is also used for the reduced current I
2
.
Important!
If F-P is set to “OFF”, the set-up parameters dcY and I-G (described below)
cannot be selected.
Pulsing status indicator: Remains lit up as long as a value has been specified for
the “F-P” parameter.
dcY
.....
D
uty
cy
cle ... Where a pulsing frequency has been set, ratio of pulse duration to
background-current duration .... 10 to 90 %, factory setting: 50 %
I-G
......
I
(current)-
G
round ... (background current) ... 0 to 100 % of main current I
1
Factory setting: 50 %
FAC
....
Fac
tory ... To reset the welding machine
Press and hold the Set button (13) for 2 s to reset the machine to the factory settings.
When the display reads “PrG”, the welding machine has been reset.
Important!
When the welding machine is reset, all the personal settings in Level 1 of
the set-up menu are lost. The parameter settings in the second level of the set-up menu
(2nd) are not deleted either.
2nd
..... Second level of the set-up menu (see “The set-up menu: Level 2”)
Available set-up
parameters
(continued)
The AC / polarity reversal set-up parameters are only available on the CastoTIG 1702 /
2202 AC/DC power sources.
-Press the “Process” button (6) to select the AC welding process
(6)
Accessing
-While pressing and holding the Set button (13), press the “Process” button (6)
-The first set-
up parameter is displayed (e.g. “ACF”)
Important!
The first parameter to be displayed is always the one that was the last to be
selected the last time the set-up menu was accessed.
Level 1: AC / polarity reversal set-up parameters
General remarks