50
tS1 | xxx, tS2 | xxx, tS3 | xxx
Cause:
Over-temperature in the secondary circuit of the power source
Remedy:
Allow the power source to cool down
tSt | xxx
Cause:
Over-temperature in the control circuit
Remedy:
Allow the power source to cool down
Err | 051
Cause:
Mains undervoltage: The mains voltage has dropped below the tolerance
range (see chapter “Technical data”)
Remedy:
Check the mains voltage
Err | 052
Cause:
Mains overvoltage: The mains voltage has risen above the tolerance range
(see chapter “Technical data”)
Remedy:
Check the mains voltage
no | IGn
Cause:
“Ignition time-out” function is active: No current started flowing before the
end of the time specified in the set-up menu. The safety cut-out of the
power source has been triggered.
Remedy:
Press the torch trigger repeatedly; clean the surface of the workpiece; if
necessary, increase the time-period specified in “Set-up menu: Level 2”
before the safety cut-out is triggered.
Err | IP
Cause:
Primary overcurrent
Remedy:
Contact After-Sales Service
Err | bPS
Cause:
Fault in power module
Remedy:
Contact After-Sales Service
dSP | Axx, dSP | Cxx, dSP | Exx, dSP | Sy, dSP | nSy
Cause:
Fault in central control and regulation unit
Remedy:
Contact After-Sales Service
no | Arc
Cause:
Arc-break
Remedy:
Press the torch trigger repeatedly; clean the surface of the workpiece
no | H2O
Cause:
Cooling-unit flow watchdog has been triggered
Remedy:
Check the cooling unit; if necessary, top up the coolant and/or vent the
water forward-flow hose as described in “Putting the cooling unit into
service”
hot | H2O
Cause:
Thermostat on cooling unit has been tripped
Remedy:
Wait until the end of the cooling phase, i.e. until “Hot | H2O” is no longer
displayed. Automatic interface AUT 2: Before resuming welding, initialise
the “Source error reset” signal.
Displayed service
codes
(continued)