49
General remarks
Displayed service
codes
If any error message that is not described here appears on the displays, then the fault is
one that can only be put right by a service technician. Make a note of the error message
shown in the display, and of the serial number and configuration of the power source,
and get in touch with our after-sales service, giving them a detailed description of the
error.
no | Prg
Cause:
No pre-programmed program has been selected
Remedy:
Select a pre-programmed program
tP1 | xxx, tP2 | xxx, tP3 | xxx, tP4 | xxx, tP5 | xxx, tP6 | xxx
Cause:
Over-temperature in the primary circuit of the power source
Remedy:
Allow the power source to cool down
The power sources are equipped with an intelligent safety system. This means that apart
from the fuse for the coolant-pump, it has been possible to dispense with melting-type
fuses entirely. After a possible malfunction or error has been remedied, the power source
can be put back into normal operation again without any melting-type fuses having to be
changed.
Warning!
An electric shock can be fatal. Before opening up the machine
-Shift the mains switch into the "OFF" position
-Unplug the machine from the mains
-
Put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again
-Using a suitable measuring instrument, check to make sure that electrical-
ly charged components (e.g. capacitors) have been discharged
Caution!
Inadequate PE conductor connections can cause serious injury and
damage. The housing screws provide a suitable PE conductor connection for
earthing (grounding) the housing and must NOT be replaced by any other
screws which do not provide a reliable PE conductor connection.
Indicating the software version:
While pressing and holding the Set button (13), press the parameter selection button (8).
The software version now appears on the displays. To exit, press the Set button (13)
again.
+