54
1702 AC/DC
2202 AC/DC
Mains voltage
230 V
230 V
Mains voltage tolerance
-20% / +15%
-20% / +15%
Mains fuse protection (slow-blow)
16 A
16 A
Primary contin. power (100% d.c.)
3.0 kVA
3.0 kVA
Cos phi
0.99
0.99
Welding current range
WIG
3 - 170 A
3 - 220 A
Elektrode
10 - 140 A
10 - 180 A
Welding current at:
10 min/25°C (77°F)
35% d.c.
170 A
-
10 min/25°C (77°F)
40% d.c.
-220 A
10 min/25°C (77°F)
60% d.c.
120 A
180 A
10 min/25°C (77°F)
100% d.c.
100 A
150 A
10 min/40°C (104°F)
30% d.c.
170 A
220 A
10 min/40°C (104°F)
60% d.c.
110 A
160 A
10 min/40°C (104°F)
100% d.c.
90 A
130 A
Open-circuit voltage
90 V
93 V
Working voltage:
TIG
10.1 - 16.8 V
10.1 - 18.8 V
Rod electrode (MMA)
20.4 - 25.6 V
20.4 - 27.2 V
Degree of protection
IP 23
IP 23
Type of cooling
AF
AF
Insulation class
B
B
Dimensions L x W x H mm (with handle)
500/175/410
500/175/410
Weight
15 kg
17.3 kg
Marks of conformity
S, CE
S, CE
Technical data
Note!
Inadequately dimensioned electrical installations can lead to serious
damage. The mains supply lead, and its fuse protection, must be dimensioned
accordingly. The technical data shown on the rating plate shall apply.
CastoTIG 1702
AC/DC / 2202 AC/
DC
Special voltages
Summary of Contents for CastoTIG
Page 2: ......
Page 4: ......
Page 16: ...ud_ca_st_sv_00676 032003 XII ...
Page 76: ...CastoTIG 2201 DC ...
Page 77: ...CastoTIG 1702 AC DC ...
Page 78: ...CastoTIG 2202 AC DC ...