16.2
Basic Message Structure
Instrument-specific system exclusive message operation can be broadly divided between two methods:
Individual Parameter Transfer (single parameter send/receive) and Bulk Parameter Set Transfer (batch
parameter send/receive). Each method includes a number of different messages.
The field in the system exclusive message that specifies the message type is the action (
act
) field.
The format of the
body
part of the message depends on the
act
value.
The table below shows the body format for each action of Instrument-specific system exclusive mes-
sages. An actual message consists of the items indicated by
Y
, from left to right.
<-
body
(Depends on
act
)
->
SX
MAN
MOD
dev
act
cat
mem
pset
blk
prm
idx
len
data
img
crc
EOX
IPR
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
-
-
-
Y
IPS
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
-
-
Y
OBR
Y
Y
Y
Y
Y
Y
Y
Y
-
-
-
-
-
-
-
Y
OBS
Y
Y
Y
Y
Y
Y
Y
Y
-
-
-
Y
-
Y
Y
Y
HBR
Y
Y
Y
Y
Y
Y
Y
Y
-
-
-
-
-
-
-
Y
HBS
Y
Y
Y
Y
Y
Y
Y
Y
-
-
-
Y
-
Y
Y
Y
EXI
Y
Y
Y
Y
Y
-
-
-
-
-
-
-
-
-
-
Y
SBS
Y
Y
Y
Y
Y
-
-
-
-
-
-
-
Y
-
-
Y
ACK
Y
Y
Y
Y
Y
Y
Y
Y
-
-
-
-
-
-
-
Y
RJC
Y
Y
Y
Y
Y
Y
Y
Y
-
-
-
-
-
-
-
Y
ESS
Y
Y
Y
Y
Y
Y
Y
Y
-
-
-
-
-
-
-
Y
EBS
Y
Y
Y
Y
Y
Y
Y
Y
-
-
-
-
-
-
-
Y
ERR
Y
Y
Y
Y
Y
-
-
-
-
-
-
-
Y
-
-
Y
16.3
Format of Each Field
16.3.1
SX : System Exclusive message Status
Format:
11110000B (F0H)
This is the System Exclusive Message status byte established by the MIDI standard.
16.3.2
MAN : Manufacturer’s ID
Format:
01000100B (CASIO = 44H)
Indicates this Instrument’s manufacturer ID.
16.3.3
MOD : Model ID
Format:
MSB
00010110B (16H)
LSB
00000011B (03H)
These two successive bytes (MSB, LSB) indicate the XW-P1/XW-G1 model ID.