— 62 —
[ 20 ] REMOTE DISPLAY Test:
[Function]
Tests whether the data is correctly displayed on REMOTE DISPLAY.
Be sure to connect REMOTE DISPLAY to COM3. When changing the baud rate, be sure to also
change the settings on REMOTE DISPLAY. The backlight turns on in pastel green (green + white)
when performing the test and turns off when the test ends.
When performing a single test:
In order to complete the test, the operator must determine pass(OK)/fail(NG) of the result.
After the operator determines pass(OK)/fail(NG), the display and the backlight turn off.
When repeating the test infinitely:
Repeats transmitting the same test text at a set interval.
Press [ESC] to terminate the test, clear the display, and turn off the backlight.
[Operation]
Operation : b n 0 2 3 ST
b:Specifying the baud rate
0
19.2 Kbps
1
9600 bps
n: Number of times
0 or no value
To perform a single test
A value other than 0 (1 ~ 9) Tests repeat infinitely (press ESC to terminate)
[LCD]
REMOTE DISP
bn023
Please Hit Key
OK−>1 NG−>9
REMOTE DISP
OK
END
bn023
[PRINT]
[REMOTE DISPLAY]
REMOTE DISP
bn023
REMOTE DISP
OK
END
bn023
ABCDEFGHIJKLMNOP
QRSTUVWXYZabcdef
0,1,2,3,4,5,6,7,8,9,