— 58 —
[ 16 ] VRAM CHECK Test
[Function]
Checks VRAM of the LCD.
All areas except for the GDC system area are subjected to this test.
VRAM is not backed up by the battery. A power failure during the test results in an error.
This test uses the same test data as RAM Test to write on VRAM.
[Operation Overview]
(1) Write the test data from the beginning to the end of VRAM Test area.
(2) Verifies the written data from the beginning to the end of VRAM Test area.
(3) Displays and prints out the test result.
* If an error occurs, the test is immediately terminated and the result is displayed and printed out.
If the test is set to repeat indefinitely, the operation returns to Step (1) and continues the test.
* When the test is set to repeat indefinitely, Steps (1) through (3) repeat as a set until [ESC] is
pressed.
[Test area]
This test targets the free areas of VRAM (TestArea).
VRAM
16MB
Display Area
(3Mbyte)
TestArea
LIME
Register Area
* LIME : Internal Memory Area
00FFFFFFh
00300000h
00FFFFFFh
01FC0000h
01FFFFFFh
00000000h
[Operation]
Operation : n 7 2 1 ST
n: Number of times
0 or no value
To perform a single test
A value other than 0 (1 ~ 9) Tests repeat infinitely (press ESC to terminate)
[LCD]
[PRINT]
LCD VRAM
721
LCD VRAM
OK
LCD VRAM
NG address
END
721
LCD VRAM
721
LCD VRAM
OK
LCD VRAM
NG address
END
721
* If an NG occurs, the address of the error is displayed /printed out.
* The counter is displayed on the LCD during the test.
Summary of Contents for QT-6600
Page 1: ...SERVICE MANUAL QT 6600 ELECTRONIC CASH REGISTER QT 6600 EX 830 NOV 2008 Ver 5 Oct 2014 ...
Page 26: ... 23 M 13 Disengage and remove the LCD Unit LCD unit ...
Page 98: ... 95 10 PCB LAYOUT MAIN PCB E830 1 PCB TOP VIEW ...
Page 99: ... 96 MAIN PCB E830 1 PCB BOTTOM VIEW ...
Page 101: ... 98 INLET PCB E830 INLET PCB MIC PCB E830 MIC PCB LED PCB E830 E6 PCB TOP VIEW BOTTOM VIEW ...