7. DIAGNOSTIC PROGRAM
7-1. Starting the Program
(1) Check that the power is turned OFF.
(2) While holding down the INIT switch, turn on the power.
(3) Release the switch when the screen below appears.
* If the switch is released before this screen appears, either of the following modes is launched.
• Power-failure recovery reboot
• INIT boot-up
(4) Enter “99990000” and press [OK].
(5) When the program is launched, the software version information is printed out as shown below.
• BOOTER
• IOC
| IOC Ver : xxxx xxxxxx
| IOC
| Boot Ver : xxxx xxxxxx
| BOOTER
(6) After the version information is displayed and printed out, a
message appears prompting for an action to take as the next
step.
To proceed with the calibration settings, press the ON/OFF
key on the display. For detailed procedures, see “[15] LCD
CALIBRATION SETTING”. If you wish to skip the calibration
settings, press anywhere on the touch panel.
Init switch
Power switch
DALLAS
DRW 1CLOSE 2CLOSE
MAC ADRS
XX-XX-XX-XX-XX-XX
TEMP 0 VOLTAGE 0 CHARGE-MODE 359M
DISP ON/OFF OFF CF NON
Ioc
Ver
: xxxxxx xxxx
Boot Ver
: xxxxxx xxxx
TOUCH START
221
Enter the Calibration mode
==>> Push Disp on/off key
Skip the Calibration mode
==>> Touch the panel
0000
00000221
PANEL SIZE 15"
Copyright(C)2008
CASIO COMPUTER CO.,LTD.
All rights reserved.
ROM VER.
xxxxxx xxxx
C
1
0
4
7
2
5
8
3
6
9
CREATE
xxxx-xx-xx xx:xx
QT-6600
Version
x.xx
APL VER.
xxxxxx xxxx
OK
Display on/off key
Summary of Contents for QT-6600
Page 1: ...SERVICE MANUAL QT 6600 ELECTRONIC CASH REGISTER QT 6600 EX 830 NOV 2008 Ver 5 Oct 2014 ...
Page 26: ... 23 M 13 Disengage and remove the LCD Unit LCD unit ...
Page 98: ... 95 10 PCB LAYOUT MAIN PCB E830 1 PCB TOP VIEW ...
Page 99: ... 96 MAIN PCB E830 1 PCB BOTTOM VIEW ...
Page 101: ... 98 INLET PCB E830 INLET PCB MIC PCB E830 MIC PCB LED PCB E830 E6 PCB TOP VIEW BOTTOM VIEW ...