— 45 —
7-6. Test Items
This program performs the following tests.
No
Device to be checked
Operation
Note
Page
1 Batch Test 1
1
RAM, FROM (for programming),
FROM (for hibernation),
Date/Time, Buzzer, Drawer,
Receipt
33
2 Batch Test 2
2
LCD,LCD backlight, REAR
DISPLAY, REAR DISPLAY
backlight
34
3 RAM WRITE/READ Test
n011
35
4 RAM READ ONLY Test
n111
35
5 FLASH ROM CLEAR Test
cn212
36
6 FLASH ROM WRITE/READ Test
cn012
37
7 FLASH ROM CLEAR & WRITE/READ Test
cn312
38
8 FLASH ROM CHECK SUM Test
n512
39
9 CF-CARD CLEAR Test
n213
39
10 CF-CARD WRITE/READ Test
n013
40
11 CF-CARD READ ONLY Test
n113
40
12 CF-CARD CLEAR & WRITE/READ Test
n313
41
13 LCD Test
n021
42
14 LCD Backlight OFF Test
121
42
15 LCD Calibration Setting
221
43
16 VRAM CHECK Test
n721
44
17 REAR DISPLAY Test
n322
45
18 REAR DISPLAY Backlight Test
cn122
46
19 REAR DISPLAY Contrast Adjustment
422
47
20 REMOTE DISPLAY Test
bn023
48
21 External Printer Output Test
x1x2x3nm3d
49
22 Ethernet Printer Output Test
x100nm37
51
23 COM(RS232C) Test
xn04d
53
24 COM (RS232C) Batch Test
40
54
25 Printing COM (RS232C) Test Result
47
55
26 Ethernet Test:
bm0a51
56
27 Setting MAC (Media Access Control Address)
x0951
58
28 Date/Time Setting
hhmmss0070
yymmdd0170
60
29 Date/Time Display
070
60
30 Drawer Test
xn091
61
31 Buzzer Test
n092
62
32 MCR Test
96
63
33 Sound Test
axn097
64
34 Microphone Test
98
64
35 Charge Mode Test
99
65
36 OBR Test
95
65
37 PS/2 Keyboard Test
r1n094
66
Summary of Contents for QT-6600
Page 1: ...SERVICE MANUAL QT 6600 ELECTRONIC CASH REGISTER QT 6600 EX 830 NOV 2008 Ver 5 Oct 2014 ...
Page 26: ... 23 M 13 Disengage and remove the LCD Unit LCD unit ...
Page 98: ... 95 10 PCB LAYOUT MAIN PCB E830 1 PCB TOP VIEW ...
Page 99: ... 96 MAIN PCB E830 1 PCB BOTTOM VIEW ...
Page 101: ... 98 INLET PCB E830 INLET PCB MIC PCB E830 MIC PCB LED PCB E830 E6 PCB TOP VIEW BOTTOM VIEW ...